2 – Operations and Administration
on the slave spine will turn on automatically when it becomes the chassis management spine.
5. Click Apply.
NOTE: For additional information on configuring the Fabric Manager, refer to the Subnet Management section of Appendix D, Switch Command Line Interface.
2.2.13.1.1
Determining the Active Fabric Manager
In a configuration with multiple switches, to determine where the master SM is, use the following host Fabric Manager command:
saquery
2.2.14
The sm_query Application
The sm_query application allows the user to view fabric information and to modify the configuration of the subnet manager. This includes:
❥Viewing and modifying the current subnet manager configuration.
❥Viewing a list of node records (i.e., hosts and switches) on the fabric.
❥Viewing a list of link records (i.e., the fabric topology).
❥Viewing a list of multicast records.
❥Viewing a list of service records.
❥Viewing switchInfo records.
❥Viewing portInfo records.
The application can be used with the
For the
Local connection method: Run the sm_query application on the same host running the
Remote connection method: Run sm_query and connect (via SNMP) to a remote host running the
For the Embedded Fabric Manager:
Remote connection method: Run sm_query remotely and connect to an embedded SNMP agent (e.g., such as one running on a SilverStorm 9240).
|