4 – EVIC Configuration and Monitoring Features Configuration
Q
Host Instance
For each instance that a host is connected to the same IOC, a unique number must be assigned. The default value is zero (range =
Host GUID
The globally unique indentifier for a host port GUID. This is the port GUID of the HCA port of the virtual port specified in a 'create' block of an /etc/sysconfig/ics_inic.cfg file of a host. This field is only valid for the viftual port(s) in use.
NOTE: For information on assigning a host connection to a specific viPort using the ethVirtAssignedHostSet command, refer to the section "Appendix D - Command Line Interface".
4.3.5.3
VLAN Configuration Example
An Ethernet network can be accessed via Ethernet port 1, which contains Ethernet hosts in VLAN 2 and Ethernet hosts in VLAN 4094. InfiniBand (IB) host 1 needs to be a member of VLAN 2 and IB host 2 needs to be a member of VLAN 4094.
In this example, IB host 1 is virtual port 1 and IB host 2 is virtual port 2. Given these parameters, the following configuration allows communication between the IB hosts and the appropriate Ethernet hosts:
Figure 4-28. VLAN Configuration Example: Ethernet Ports
Figure 4-29. VLAN Configuration Example: Host Ports
NOTE: The PVID on the Ethernet port does not need to be changed since all frames received from the Ethernet network will have VLAN tags and
|