1-2. Notes on Creation of Logical Drive

„Setting hot-spare disk

FastBuild Utility cannot set hot-spare disks. To set hot-spare disks, use the disk array controller management utility WebPAM after OS is installed.

For free HDDs unassigned to any logical drives, standby rebuild can be done but media patrol cannot. It is recommended to specify such free HDDs as spare disks by using WebPAM.

„Logical drive configuration using split function

The disk array controller can make various logical drive configurations under the support of the split function. However, note that some configurations may cause faults to occur. Examples of recommended and unsupported configurations of logical drives are described below. See the examples before creating logical drives.

(1)Recommended split configuration

(1-1) Configuration of logical drives in the same RAID level by HDDs having the same capacity

Disk array controller

LD1-1

LD1-2

LD1-3

RAID5

80GB

80GB

80GB

LD size: 160GB

LD2-1

LD2-2

LD2-3

RAID5

40GB

40GB

40GB

LD size: 80GB

Disk 1

Disk 2

Disk 3

 

(120GB)

(120GB)

(120GB)

 

Page 104
Image 104
NEC N8103-89 manual Recommended split configuration