Note the following for the rebuild:

„The HDD to be used for rebuild should have the same capacity, number of revolutions, and standard as the defected HDD.

Notice „ During rebuild, the processing rate is decreased due to much load.

„During rebuild, do not shut down or reboot the server. If the server is shut down by an unforeseen accident such as power interruption, turn on the power again as soon as possible. The rebuild is automatically restarted.

„For the hot-swap rebuild, an additional HDD cage is required.

„The interval from the removal of the defected HDD to the installation of a substitute HDD should be 90 sec or longer.

„If the hot-swap rebuild does not operate, perform the manual rebuild.