97
3-3. Logical Drive Creation Procedure
1.Start FastBuild Utility.
2.Press the [1] key on the Main Menu to activate [View Drive Assignments].
FastBuild (tm) Utility (c)
| [ View Drives Assignments ] |
| |
Channel:ID | Drive Model | Capacity (MB) | Assignment |
1:Mas MAXTOR 6Y080MO | 80001 |
| |
| Extent 1 | 79933 | Free |
2:Mas MAXTOR 6Y080MO | 80001 |
| |
| Extent 1 | 79933 | Free |
3:Mas MAXTOR 6Y080MO | 80001 |
| |
| Extent 1 | 79933 | Free |
4:Mas MAXTOR 6Y080MO | 80001 |
| |
| Extent 1 | 79933 | Free |
[ Keys Available ]
[↑] Up | [↓] Down | [ESC] Exit |
3.Check the connection status of HDDs connected to each channel.
[Checking items]
Whether all HDDs connected to the disk array controller is recognized.
Whether the capacities of the HDDs are indicated correctly and whether all the HDDs have the same capacity.
Whether every "Assignment" is set to "Free."
If HDDs of different capacities are connected, contact your service representative.
If a new HDD or a HDD replaced for maintenance is connected and
Notice "Assignment" is set to "LD
4.After making sure that all the HDDs are indicated and connected correctly, press the [Esc] key to return to the Main Menu.