TP-Link TL-SL2210WEB/TL-SL2218WEB, TL-SL2428WEB/TL-SL2452WEB manual Priority Setting, Priority Mode

Page 53

Gigabit Uplink Web Smart Switch

FFFFFFFFFFFFPort Trunking

¾¾ Trunk: The Trunk number.

¾¾ Member: Select the member of the Trunk here. Each group has 4 optional ports to compose a Trunk.

¾¾ Storm Control: configure the storm control for the Trunk here. All member ports of the Trunk share the same settings. Subfield of the Storm Control are the same as that of the port storm control, see phase 6.3.2.4 for details.

¾¾ Select All: Select all Trunk members in the list.

¾¾ Clean Up: Clean up the Trunk member list.

Note:

Each Trunk should contains 2 to 4 ports (If a Trunk is submitted with 0 member port, it indicates to delete the Trunk\.

SFP and 1000Mbps port in TL-SL2210WEB/TL-SL2218WEB/TL-SL2428WEB/TL- SL2452WEB, is not able to be the Trunk member.

Trunks cannot be set if the switch is in MTU VLAN mode.

666666 Priority Setting

Priority setting contains four topics: priority mode, port-based priority, port default priority and 802.1p priority.

Because dynamic menu is adopted, only the pages corresponding to current priority mode are revealed. If the parameters of other priority modes are to be configured, select the corresponding priority mode in “Priority Mode” page first.

66666666 Priority Mode

This page is shown below:

FFFFFFFFFFFF Priority Mode

Web Management 46

Image 53
Contents User Guide Page CE Mark Warning Copyright & Trademarks FCC StatementRelated Document About this User Guide Conventions AudienceContents WEB Management Product Overview FeaturesCccccccccc Introduction Front Panel AppearanceReset Rear Panel Safety Precautions CCCCCCCCCCInstallationPackage Contents Site Requirements Lightening Protection Product Installation Installation ToolsFffffffffff Bracket Installation Cabling Reasonably Cccccccccc Lightning ProtectionRequirements for Cabling Indoors Connect to Ground SFP Port CCCCCCCCCCConnectionEthernet Port Power On Verify InstallationCCCCCCCCCCFunction Description Port Security Flow ControlPort Statistic and Port Status Storm ControlAging Time and Dynamic Address Table Network SettingDynamic Binding Static MAC Address TableFiltering MAC Address Table Ping Vlan SettingVlan Mode Port-Based Priority Priority Setting Priority ModePort Trunking 555555 802.1p Priority Port Default PriorityPort Mirroring Virtual Cable TestOverview Connecting to the Device Getting StartedCcccccccccweb Management Fffffffffff Settings Dialog Dialog will pop up as below Setting the Device Login the SwitchGigabit Uplink Web Smart Switch ¾¾ Port Trunking Port Trunking System Information Further explanation Port Setting Ffffffffffff Port Parameter 66666666Port Statistic 66666666Storm Control Port Status66666666Port Description Static MAC Address Switch IP AddressFFFFFFFFFFFFStatic MAC address Filtering MAC Address 66666666Dynamic Binding Bound MAC Address Aging Time Vlan Setting Vlan Mode 66666666Port Vlan Setting 66666666Tag Vlan Global Setting 66666666Tag Vlan Setting MTU Vlan Setting Priority Setting 66666666Port-Based Priority 66666666802.1p Priority Class FFFFFFFFFFFFVirtual Cable Test Qqqq Why does the Power LED work abnormally? Appendix a TroubleshootingAppendix B Table of Factory Defaults Pvid Appendix C Table of Function Differences of Switch Family FCC, CE Appendix D Hardware SpecificationsAppendix E Technical Support Page 7106503690 Rev