DC Power Input

 

 

Interfaces

Euro type terminal block contacts

 

(DC1 DC2 : 2 sets for power wire cascading)

 

DC Jack ( -D 6.3mm / + D 2.0mm)

Operating Input Voltages +7V ~ +30V(+5%)

 

Power consumption

Model 800M

4.7W/7.5VDC input, 5.0W/30VDC input

 

Model 800M-1

6.0W/7.5VDC input, 6.3W/30VDC input

 

Model 800M-2

8.0W/7.5VDC input, 8.3W/30VDC input

Mechanical

 

 

Dimension (base)

140 x 106 x 40 mm

 

Housing

Enclosed metal with no fan

Mounting

Support DIN-rail mounting, Panel mounting

Weight

Model 800M: 465g, Model 800M-1: 475g, Model 800M-2: 485g

Environmental

 

 

Operating Temperature

Typical -20oC ~ 70oC

Storage Temperature

-20oC ~ 85oC

 

Relative Humidity

5% ~ 90%

 

Electrical Approvals

 

 

FCC

Part 15 rule Class A

CE

EMC, CISPR22 Class A

1.8 Model Definitions

Model

TP Port

FX Port

Connector

Cable

Distance max.

Operating Temperature

800M

P1-P8

no

 

 

 

-20oC ~ 70oC

800M-1T

P1-P8

FX8

ST

M M F

2km

-10oC ~ 70oC

800M-1C

P1-P8

FX8

SC

M M F

2km

-10oC ~ 70oC

800M-1CL1

P1-P8

FX8

SC

M M F

2km

-20oC ~ 70oC

800M-1CL2

P1-P8

FX8

SC

M M F

2km

-20oC ~ 70oC

800M-1SA2

P1-P8

FX8

SC

SMF

15km

-20oC ~ 70oC

800M-1SL2

P1-P8

FX8

SC

SMF

20km

-20oC ~ 70oC

800M-1SL2B

P1-P8

FX8

SC

SMF

20-30km

-20oC ~ 70oC

800M-2T

P1-P8

FX7

ST

M M F

2km

-10oC ~ 70oC

 

 

FX8

ST

M M F

2km

 

800M-2C

P1-P8

FX7

SC

M M F

2km

-10oC ~ 70oC

 

 

FX8

SC

M M F

2km

 

800M-2CL1

P1-P8

FX7

SC

M M F

2km

-20oC ~ 70oC

 

 

FX8

SC

M M F

2km

 

800M-2CL2

P1-P8

FX7

SC

M M F

2km

-20oC ~ 70oC

 

 

FX8

SC

M M F

2km

 

800M-2SA2

P1-P8

FX7

SC

SMF

15km

-20oC ~ 70oC

 

 

FX8

SC

SMF

15km

 

800M-2SL2B

P1-P8

FX7

SC

SMF

20-30km

-20oC ~ 70oC

 

 

FX8

SC

SMF

20-30km

 

800M-2SL2

P1-P8

FX7

SC

SMF

20km

-20oC ~ 70oC

 

 

FX8

SC

SMF

20km

 

800M-2MCSL2B

P1-P8

FX7

SC

M M F

2km

-20oC ~ 70oC

 

 

FX8

SC

SMF

20-30km

 

800M-2MCSL2

P1-P8

FX7

SC

M M F

2km

-20oC ~ 70oC

 

 

FX8

SC

SMF

20km

 

-14-

Image 14
Contents Installation Guide KSD-800MPage Trademarks Table of Contents Snmp Management Plug and Play IntroductionModel series 10/100TX TP Ports 100FX fiber ports Auto Copper/Fiber ConnectionsBasic functions FeaturesDesigned for Industrial Applications Management functionsProduct Panels Front Panel Network PortsLED Indicators FunctionSpecifications Top Panel10/100TX Twisted Pair Ports Switch FunctionsLED Indicators Vlan Function Port Configuration Control FunctionSoftware Management Functions QoS FunctionMechanical DC Power InputModel Definitions EnvironmentalOptical Specifications Unpacking InstallationSafety Cautions DIN-Rail Mounting Panel Mounting Page Applying Power Using Terminal BlocksPower Failure Relay Output Using DC Power JackReset Button Making UTP ConnectionsFar End Fault Function Making Fiber ConnectionsLED Indication Function State InterpretationConfiguring Snmp Settings Configuring IP Address for the SwitchConfiguring User Name and Password Configuring Port 7 and PortQoS Function Egress Service PolicyAdvanced Functions Priority LevelDscp Classification per port setting Port-based Priority Setting per port setting3.2 802.1p Classification per port setting User Defined Dscpa Classification GlobalUser Defined IPA Classification Global Other QoS SettingsIP Network Address Classification User Defined IPB Classification GlobalVlan Function Vlan OperationUnmatched VID Filtering per port setting 2.1 802.1Q Tag Aware Vlan Mode global settingIngress Member Filtering global setting Ingress RulesPacket Forwarding under Vlan Egress Tag Rule per port settingVlan Group Mapping Egress Tagging RulesNull VID Replacement per port setting Summary of Vlan FunctionMain Menu Software ManagementTelnet Management Interface IP Settings Description IP MenuSnmp Settings Description Snmp MenuPort Config Status DescriptionPort Setting Description AdministratorAdministrator Vlan Settings Vlan Information Description Vlan IDInput Description Vlan Global Settings DescriptionVID Setting Description Per Port Settings Description Tagging with ingress Pvid for all packetsAdministrator QoS Settings Select 1 Show QoS Other Status to view other settings global QoS Other Settings Description Restore Default Values Security ManagerSetting Description Update FirmwareReboot System ExitStart Browser Software and Making Connection Login to the Switch UnitWeb Management Page Port Status Menu Port Status DescriptionBasic Menu Menu FunctionSnmp Entries IP Address IP Address Setting DescriptionSystem Settings Description Community Settings Description Port Controls Trap Manager Settings DescriptionPort Settings Description Vlan Controls Ingress Rules Global Settings DescriptionVlan Group Configuration Group Settings Description Per Port Settings Egress Rules Insertion for untagged packets only is selectedQoS Per Port Settings Description QoS ControlsQoS Global Settings Description IPA address and IPA subnet mask specify IPA user defined Settings Description Image Refresh TimeRestore Default Snmp Traps Snmp ManagementMIB Objects ObjectsAppendix. Factory Default Settings QoS Settings