Dukane 8915 user manual Air filter

Page 58
Turn the projector on, and reset the filter time using the FILTER TIME function of OPTION menu (39).
Position the cleaned air filter or a new air filter into place, and push the points of "PUSH" word with claws to fix the air filter.
Filter cover’s claws
Filter cover
Air filter’s knob
Air filter

Maintenance

Air filter

WARNING ►Before caring, make sure the power switch is off and the power cable is not plugged in, then allow the projector to cool sufficiently. The care in a high temperature state of the projector could cause a burn and/or malfunction to the projector.

►Use only the air filter of the specified type. Do not use the projector with the air filter and filter cover removed.

►Avoid wetting the projector or inserting liquids in the projector. It could result in a fire, an electric shock, and/or malfunction to the projector.

CAUTION ►Please replace the air filter when it is damaged or too soiled, and also when you replace the lamp.

When the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible. If the air filter becomes clogged by dust or the like, internal temperatures rise and the power may be automatically turned off for malfunction prevention.

1. Turn the projector off, and unplug the power cord.

Allow the projector to cool for at least 45 minutes. And prepare a vacuum cleaner.

2. After making sure that the projector is cool adequately, slowly turn the projector so that the lens-side is facing

up. Please be careful for a projector not to fall. While the projector is placed lens-side up, hold the projector.

3. Unhooking the filter cover’s claws, pull the filter cover in the direction of the arrow to remove it.

4. Holding the air filter’s knob, pull the air filter off.

5. Apply a vacuum cleaner to the vent of the projector for the air filter. And then slowly turn the projector bottom up.

6. Apply a vacuum cleaner to the air filter and filter cover. Please replace the air filter when it is damaged or too soiled.

To prepare a new air filter, contact your dealer and tell the air filter type number = NJ20642.

An air filter of specified type will come even with the replacement lamp for this projector.

7.

8. Replace the filter cover and snap it back into place.

9. Slowly turn the projector so that the top is facing up.

10.

NOTE • Incorrectly resetting of the filter timer (resetting without replacement, or neglect of resetting after replacement) will result in incorrect message functions.

46

Image 58
Contents LCD Projector Model Page About The Symbols Safety Precautions Safety Precautions Be careful in handling the light source lamp Be careful in moving the projector Do not give the remote control any physical impact Take care not to fatigue your eyes Lamp Regulatory Notices Page Thank you for purchasing this projector About this manualTrademark acknowledgment Contents About contents of package Fastening the lens cap Component Part namesProjector P B P RControl buttons Remote controlLaser Indicator 14 STANDBY/ONSetting up At 43 screen ArrangementAt 169 screen Adjusting the projectors elevator About the filter cover for bottom-up use Connecting your devices About Plug-and-Play capabilityConnecting to a speaker with amplifier output Connecting to a monitor outputExamples of connection with a computer Component video out RGB cable RGB out LAN portLAN cable CAT-5 CB/PBConnecting power supply Laser pointer Remote controlPutting batteries Using the remote control Turning off the power Power on/offTurning on the power STANDBY/ONOperating Adjusting the volumeSelecting an input signal Temporarily muting the soundPress the ONE Touch button on the remote control. This Adjusting screen with ONE-TOUCHAdjusting the zoom and focus Selecting an aspect ratio At a RGB signal Using the automatic adjustment featureAdjusting the position  At a video signalUsing the magnify feature Correcting the keystone distortionsFreezing the screen Temporarily blanking the screenOperating the computer screen Available function Remote control operationUSB mouse and keyboard control At the Easy Menu Multifunctional settingsUsing the menu function At the advanced MenuEasy Menu Mirror ResetEasy Menu Filter TimePicture Menu GammaColor Temp Picture MenuHigh  Middle  LOW  Custom SharpnessSAVE4 SAVE3  SAVE2  SAVE1 LOAD1  LOAD2  LOAD3  LOAD4MY Memory Over Scan PhaseImage Menu PositionSize Auto AdjustImage Menu Execute3D-YCS Video Qlty. MenuProgressive Video NRVideo Format Input MenuDVI Input Menu InformationStereo Setup MenuVolume IR RemoteOSD Bright Screen MenuMenu Position Bright  DarkMy Screen Screen MenuStart UP My Screen LockNo Input is Detected MessageSync is OUT of Range Auto Search Option MenuONE Touch Auto OFFOption Menu Network Menu Network Menu When your network enables the Dhcp functionEx. Case of IP Address = Screen Network Menu Maintenance LampCase of replacement by yourself LampAir filter Page Related messages Internal portion temperature is rising Related messagesRegarding the indicator lamps Regarding the indicator lamps These has not been properly fixed Electrical power cord is not pluggedPower switch is not set to the on position Phenomenon Cases not involving a machine defect ReferencePhenomena that may easily be mistaken for machine defects RGB input SpecificationDigital RGB input Video input RGB output Communication portSpecifications Page Vesa Text Example of computer signalVesa Initial set signals Connection to the ports RGB in 1, B RGB in 2, C RGB OUTDVI -D CTS Audio in Ø3.5 stereo mini jack, J K Audio INL/R RCA jackRTS DC OUTCommunications setting Connecting the cableRS-232C Communication Using the projector default settings Reset Command Requesting projector status Get commandChanging the projector settings Set command Increasing the projector setting value Increment commandCRC Be EF FB FA Color Temp Gain G Progressive Color Space Mute OSD Bright Dukane Corporation Audio Visual Products