Dukane 8111H user manual Command Format, TCP #9715, Send Data format, Reply Error code

Page 46

3. Network Functions

3.7 Command Control via the Network (continued)

Command Format

Command formats differ among the different communication ports.

TCP #23

You can use the RS-232C commands without any changes. The reply data format is the same as the RS-232C commands. (“RS-232C Communication” in the User’s Manual – Operating Guide (Technical)) However, the following reply will be sent back in the event of authentication failure when authentication is enabled.

<Reply in the event of an authentication error>

Reply

Error code

0x1F

0x04

0x00

TCP #9715

Send Data format

The following formatting is added to the header (0x02), Data length (0x0D), Checksum (1 byte) and Connection ID (1 byte) of the RS-232C commands. (“RS-232C Communication” in the User’s Manual – Operating Guide (Technical))

Header

Data length

RS-232C command

Check Sum

Connection

 

 

 

 

 

ID

 

 

 

 

 

0x02

 

0x0D

13 bytes

1 byte

1 byte

Header

0x02, Fixed

 

 

Data length

RS-232C commands byte length (0x0D, Fixed)

RS-232C commands →

RS-232C commands that start with 0xBE 0xEF

 

 

 

(13 bytes)

 

 

Check Sum

This is the value to make zero on the addition of the

 

 

 

lower 8 bits from the header to the checksum.

Connection ID

Random value from 0 to 255 (This value is attached

 

 

 

to the reply data)

 

 

46

Image 46
Contents MY Image Still Image Transfer Display Thank you for purchasing this projectorWeb control Messenger FunctionConfiguring and controlling the projector via a web browser Content Main functionsEquipment connection and network setting Network FunctionsConfiguring and controlling via a web browser MY Image Still image Transfer DisplayMessenger Function Setup menu in the User’s Manual Operating Guide Required equipment preparationEquipments connection Manual network connection settingNetwork settings Open Network Connections. .2.2.bManual network connection setting Set IP address, subnet mask and default gateway for computerSetting automatically About IP address Setting manuallyFor example Internet Option setting Click3.c Local Area Network LAN Settings window Check connectionCommand Control via the Network Configuring and Controlling the Projector via a Web BrowserProjector Management using Snmp Mail AlertsConfiguring and controlling the projector via a web browser Configuring and controlling the projector via a web browser Password LogonOnly displayed when logged on using an Administrator ID Projector Name Displays the projector name settingsDisplays the Dhcp configuration settings Network InformationDisplays and configures network settings Port Settings Displays and configures communication port settingsClick Apply button to save the settings Send mail Mail SettingsDisplays and configures e-mail addressing settings Smtp Server AddressAuthentication Failure Alert SettingsDisplays and configures failure & alert settings Cold StartAlert Items are shown below Schedule Settings Displays and configures schedule settingsDescription Schedule Date Month/DayDisplays and configures the date and time settings Date/Time SettingsFirst, 2, 3, 4, Last Time difference CycleSecurity Settings Community name Configures the community name if Snmp is usedUp to 64 alphanumeric characters Projector Control Adjusts the vertical picture position Adjusts the horizontal picture positionHdmi Detected Projector Status Displays the current projector statusRestarts the projector’s network connection When Logoff is clicked, the Logon menu is displayed. 14Network Restart LogoffMail Settings 19 Mail AlertsMail Alerts Projector Management using Snmp Snmp Settings 17Event Scheduling Schedule Settings 22 Event SchedulingDate/Time Settings 24 Manual conciseStill Image Transfer MY Image Still Image Transfer Display Network Restart on the main menuMessenger Function Messenger Function Following two ports are assigned for the command control Command Control via the NetworkCommunication Port Command Control via the Network Header Data length RS-232C command Check Sum Connection Command FormatReply Error code TCP #9715Reply Data format Authentication Automatic Connection BreakConnecting devices LAN port Control portOperating Guide Communication setupCondition Transmission method HALF-DUPLEXHALF-DUPLEX FULL-DUPLEXDukane Corp AV Service Dept