Planar PR9030 user manual Alert Items are shown below

Page 21

3.Management with Web browser software

3.1Configuring and controlling the projector via a web browser (continued)

The Alert Items are shown below.

Setting Item

Description

 

 

Alarm Time

Configures the time to alert.

(Only Lamp Time Alarm and Filter Time Alarm.)

 

SNMP Trap

Click [Enable] check box to enable SNMP Trap alerts.

Send Mail

Click [Enable] check box to enable e-mail alerts.

(Except Cold Start and Authentication Failure.)

 

 

Configures the subject line of the e-mail to be sent.

Mail Subject

The length of the subject line can be up to 100 alphanumeric

characters.

 

 

(Except Cold Start and Authentication Failure.)

 

Configures the text of the e-mail to be sent.

Mail Text

The length of the text can be up to 1024 alphanumeric

characters.

 

 

(Except Cold Start and Authentication Failure.)

Click [Apply] button to save the settings.

NOTE • The trigger of Filter Error e-mail is depending on the FILTER MESSAGE setting in the SERVICE item of the OPTION Menu which defines the period until the filter message is displayed on the projector screen. The e-mail will be sent when the filter timer exceeds 500, 1000, 1500 or 2000 hours based on the configuration. No notification e-mail will be sent if the FILTER MESSAGE is set to TURN OFF. (OPTION Menu in the User’s Manual – Operating Guide)

Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of the lamp timer. When the lamp hour exceeds this threshold that is configured through the Web page, the e-mail will be sent out.

Filter Time Alarm is defined as a threshold for e-mail notification (reminder) of the filter timer. When the filter hour exceeds this threshold, the e-mail will be sent out.

19

Image 21
Contents PR9030 LCD Projector Page Web control Thank you for purchasing this projectorMY Image Still Image Transfer Display Trademark acknowledgmentEquipment connection and network setting Content Main functionsConfiguring and controlling the projector via a web browser Management with Web browser softwareMY Image Still image Transfer Display Configuring and controlling via a web browserRequired equipment preparation Network settings Manual network connection settingEquipments connection Open Network Connections. .2.2.bSet IP address, subnet mask and default gateway for PC Manual network connection settingAbout IP address Setting manually Setting automaticallyFor example Click Internet Option settingCheck connection 3.c Local Area Network LAN Settings windowProjector Management using Snmp Configuring and Controlling the Projector via a Web BrowserCommand Control via the Network Mail AlertsConfiguring and controlling the projector via a web browser Configuring and controlling the projector via a web browser Logon PasswordDhcp Network InformationDisplays and configures network settings Dhcp onDhcp OFF Port Settings Displays and configures communication port settingsClick Apply button to save the settings Displays and configures e-mail addressing settings Mail SettingsAlert Settings Displays and configures failure & alert settingsPortion has become heated Alert Items are shown below Displays and configures schedule settings Schedule SettingsDescription Schedule Schedule settings are shown belowDate Month/Day Data Date/Time Settings Displays and configures the date and time settingsFirst, 2, 3, 4, Last Sntp Time differenceSntp Server IP AddressSecurity Settings Snmp Configures the community name if Snmp is usedProjector Control Selects the Hdmi setting Selects the 3D-YCS setting3D-YCS HdmiSRS WOW Is detected Displays the current projector status Projector StatusNetwork Restart When Logoff is clicked, the Logon menu is displayed. 13Restarts the projector’s network connection LogoffMail Alerts Mail Settings 17Mail Alerts Snmp Settings 16 Projector Management using SnmpEvent Scheduling Event Scheduling Schedule Settings 20Date/Time Settings 22 Still Image Transfer MY Image Still Image Transfer Display Command Control via the Network Command Control Settings 16Communication Port Command Control via the Network Reply Error code Command FormatHeader Data length RS-232C command Check Sum Connection Send Data formatReply Data format Automatic Connection Break AuthenticationPlanar Systems, Inc