Mitsubishi 2033D SERIES technical manual AUPS Terminal Designation 30kVA UPS

Page 39

MITSUBISHI

2033D SERIES UPS

Page Number:

ELECTRIC

OWNERS / TECHNICAL MANUAL

3-7

FIGURE 3.1-aUPS Terminal Designation (30kVA UPS)

AC Bypass

Input

Terminals:

A40,B40,C40

AC input

Terminals: A, B, C

 

 

 

 

Static Transfer

 

Maintenance

 

 

 

 

 

 

 

 

 

Switch

 

Bypass Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52RS

CONVERTER INVERTER

52RC

FI

FO

52C

FB

72B

BATTERY

UPS Module

Terminals:

A50,B50,C50,

N50

Output

FIGURE 3.1-bUPS Terminal Designation (50kVA, 80kVA UPS)

AC Bypass Input

Terminals:

A40,B40,C40

AC input

Terminals: A, B, C

52RC FI

Static Transfer

Switch

52RS

CONVERTER INVERTER

FO

52C

FB

 

72B

 

DC input Terminals: BP, BN

Battery

Cabinet

Maintenance Bypass Switch

UPS Module

Terminals:

A50,B50,C50,

N50

Output

MITSUBISHI ELECTRIC 2033D SERIES UPS

Image 39
Contents ALN-H0963 Preface Table of Contents UPS Module Information List of TablesList of Figures How to use this Manual Introduction Important Safety Instructions Retain These InstructionsCapacity kVA General Mitsubishi 2033D Series UPS Normal Operation OverviewInternal Static Bypass Line Single Line Diagram Battery Operation Inverter supply at battery operationPCB External Contact Signal Terminal IOAU-05 Mitsubishi 2033D Series UPS Specifications Static Bypass Input AC InputRating of Contactors and Fuses 540V 48A Operator Controls and IndicatorsLoad on bypass Load on Bypass green Battery operation Battery OP. yellowEPO button Emergency Power Off button LED Display Load on inverter Load on Inverter greenLiquid Crystal Display MenusStart/Stop screen Figure Measurement Menu Figure Start/Stop screenSetup Menu Figure 11 Main screen Input Power Failure13 Main screen Fault indication Fault Indication FigureTN1 External Signal Terminal BlockRemote EPO TN216 Control Wiring for External Contacts Output Contacts for external alarm annunciationTerminals 3 to 4 Remote Inverter Stop input terminal IN2 Terminals 33 to 34, 35 to 36 Minor Fault contact OUT8Terminals 37 to 38, 39 to 40 Total Alarm contact OUT9 Input Contacts for remote access of UPSTerminals 13 to 14 Charger IL. contact input IN7 Terminals 5 to 6 Battery Temp. High contact input IN3Terminals 7 to 8 Power Demand Command contact input IN4 Terminals 11 to 12 Asynchronous contact input IN6Pin Not used External communication connectorMitsubishi Electric 2033D Series UPS Mitsubishi 2033D Series UPSElectric Owners / Technical Manual BatteryProcedure for Cable Connections External Battery SupplyMitsubishi 2033D Series UPS Recommended cable size and torque requirements Crimp Type Compression Lug AUPS Terminal Designation 30kVA UPS BN,BP BN BP AC Bypass Input UPS-1 UPS-2 IOAU-05 TN2 IFAU-01Critical Load Cabinet Operating Procedures UPS Start-up Procedure UPS Shutdown ProcedureEPO Emergency Power Off Procedure Maintenance bypass set-up procedures Transfer of load from inverter to maintenance bypassTransfer of load from maintenance bypass to inverter Electric Owners / Technical Manual Response to UPS Failure UPS FaultUPS Component Parts Parts ReplacementContact Mitsubishi Electric Automation, Inc. at Fault CodesMitsubishi Code ListINV. or Conv Inverter Overload DC circuit failure Mitsubishi Electric Automation Inc 847