Mitsubishi 2033D SERIES technical manual UPS-1 UPS-2 IOAU-05 TN2, IFAU-01, Critical Load Cabinet

Page 43

MITSUBISHI

2033D SERIES UPS

Page Number:

ELECTRIC

OWNERS / TECHNICAL MANUAL

3-11

 

FIGURE 3.4 Diagram of Power Wire & Control Wire Connect ( Parallel connection )

 

UPS-1

 

 

 

UPS-2

 

 

 

 

 

 

IOAU-05

25

 

 

 

 

 

 

TN2

 

26

 

 

 

 

 

 

 

 

 

 

 

IOAU-05

25

 

 

 

 

 

 

 

TN2

 

26

 

IFAU-01

 

IFAU-01

 

 

 

20

In

In

B1

A2

Out

Out

10

 

 

 

 

In

B2

A1

Out

 

 

 

 

 

 

Out

A1

B2

In

 

 

 

 

10

Out

Out

A2

B1

In

In

20

 

 

 

 

 

 

 

 

 

 

AC Output

 

 

A50

 

 

 

 

A

 

AC Output

B50

 

 

 

 

B

UPS-1

C50

 

 

 

 

C

 

 

 

 

 

 

 

 

N40/N50

 

 

 

 

N

 

 

 

 

 

 

 

 

A50

A

 

 

 

 

 

AC Output

B50

B

UPS-2

 

 

 

 

 

 

 

C50

C

 

 

 

 

 

 

 

N40/N50

N

 

Critical Load Cabinet

 

1

 

 

 

 

52L1-AX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

52L2-AX

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

TB1

MITSUBISHI ELECTRIC 2033D SERIES UPS

Image 43
Contents ALN-H0963 Preface Table of Contents UPS Module Information List of TablesList of Figures How to use this Manual Introduction Important Safety Instructions Retain These InstructionsCapacity kVA General Mitsubishi 2033D Series UPS Normal Operation OverviewInternal Static Bypass Line Single Line Diagram Battery Operation Inverter supply at battery operationPCB External Contact Signal Terminal IOAU-05 Mitsubishi 2033D Series UPS Specifications Static Bypass Input AC InputRating of Contactors and Fuses 540V 48A Operator Controls and IndicatorsLoad on bypass Load on Bypass green Battery operation Battery OP. yellowEPO button Emergency Power Off button LED Display Load on inverter Load on Inverter greenMenus Liquid Crystal DisplayStart/Stop screen Figure Measurement Menu Figure Start/Stop screenSetup Menu Figure 11 Main screen Input Power Failure13 Main screen Fault indication Fault Indication FigureTN1 External Signal Terminal BlockRemote EPO TN216 Control Wiring for External Contacts Output Contacts for external alarm annunciationTerminals 3 to 4 Remote Inverter Stop input terminal IN2 Terminals 33 to 34, 35 to 36 Minor Fault contact OUT8Terminals 37 to 38, 39 to 40 Total Alarm contact OUT9 Input Contacts for remote access of UPSTerminals 13 to 14 Charger IL. contact input IN7 Terminals 5 to 6 Battery Temp. High contact input IN3Terminals 7 to 8 Power Demand Command contact input IN4 Terminals 11 to 12 Asynchronous contact input IN6Pin Not used External communication connectorMitsubishi Electric 2033D Series UPS Mitsubishi 2033D Series UPSElectric Owners / Technical Manual BatteryProcedure for Cable Connections External Battery SupplyMitsubishi 2033D Series UPS Recommended cable size and torque requirements Crimp Type Compression Lug AUPS Terminal Designation 30kVA UPS BN,BP BN BP AC Bypass Input IFAU-01 UPS-1 UPS-2 IOAU-05 TN2Critical Load Cabinet UPS Shutdown Procedure Operating Procedures UPS Start-up ProcedureEPO Emergency Power Off Procedure Transfer of load from inverter to maintenance bypass Maintenance bypass set-up proceduresTransfer of load from maintenance bypass to inverter Electric Owners / Technical Manual Response to UPS Failure UPS FaultUPS Component Parts Parts ReplacementContact Mitsubishi Electric Automation, Inc. at Fault CodesMitsubishi Code ListINV. or Conv Inverter Overload DC circuit failure Mitsubishi Electric Automation Inc 847