1.2Definitions

UNINTERRUPTIBLE POWER SUPPLY SYSTEM (UPS) - All components within the UPS Module Cabinet and associated batteries that function as a system to provide continuous, conditioned AC power to a load. This is sometimes referred to as the "System".

UPS MODULE CABINET - The metal enclosure which contains the Converter, the Inverter, the Chopper, the Static Transfer Switch, the Internal Bypass line, the operator controls, and the internal control system required to provide specified AC power to a load.

UPS MODULE - The Converter and Inverter assemblies which, under the direction of the internal control system and operator controls, provide specified AC power to a load.

CONVERTER/BOOSTER - The UPS components which contain the equipment and controls necessary to convert input AC power to regulated DC power required for battery charging and for supplying power to the Inverter.

INVERTER - The UPS components which contain the equipment and controls necessary to convert DC power from the Converter, or the battery, to AC power required by the critical load.

CHOPPER - The UPS components which contain the equipment and controls necessary to charge the battery and supply power to the Inverter from battery.

STATIC TRANSFER SWITCH - The device which connects the critical load to the bypass line when the UPS module cannot supply continuous power.

BYPASS LINE - The line which conducts electricity directly from the input power source to the critical load during Maintenance or whenever the UPS is not completely operational.

INPUT POWER - Power provided by the electrical utility company, or auxiliary generator, which is connected to the UPS for supplying the critical load.

BATTERY - The rechargeable battery strings which supply DC power to the inverter to maintain continuous AC power to the load during AC input power failure conditions

MITSUBISHI ELECTRIC 2033D SERIES UPS

Image 10
Contents ALN-H0963 Preface Table of Contents List of Tables UPS Module InformationList of Figures How to use this Manual Important Safety Instructions Retain These Instructions IntroductionCapacity kVA General Mitsubishi 2033D Series UPS Overview Normal OperationInternal Static Bypass Line Inverter supply at battery operation Single Line Diagram Battery OperationPCB External Contact Signal Terminal IOAU-05 Mitsubishi 2033D Series UPS Specifications AC Input Static Bypass InputRating of Contactors and Fuses Operator Controls and Indicators 540V 48ALED Display Load on inverter Load on Inverter green Battery operation Battery OP. yellowEPO button Emergency Power Off button Load on bypass Load on Bypass greenMenus Liquid Crystal DisplayStart/Stop screen Figure Start/Stop screen Measurement Menu FigureSetup Menu Figure Input Power Failure 11 Main screenFault Indication Figure 13 Main screen Fault indicationExternal Signal Terminal Block TN1TN2 Remote EPOOutput Contacts for external alarm annunciation 16 Control Wiring for External ContactsInput Contacts for remote access of UPS Terminals 33 to 34, 35 to 36 Minor Fault contact OUT8Terminals 37 to 38, 39 to 40 Total Alarm contact OUT9 Terminals 3 to 4 Remote Inverter Stop input terminal IN2Terminals 11 to 12 Asynchronous contact input IN6 Terminals 5 to 6 Battery Temp. High contact input IN3Terminals 7 to 8 Power Demand Command contact input IN4 Terminals 13 to 14 Charger IL. contact input IN7External communication connector Pin Not usedMitsubishi 2033D Series UPS Mitsubishi Electric 2033D Series UPSBattery Electric Owners / Technical ManualExternal Battery Supply Procedure for Cable ConnectionsMitsubishi 2033D Series UPS Recommended cable size and torque requirements Crimp Type Compression Lug AUPS Terminal Designation 30kVA UPS BN,BP BN BP AC Bypass Input IFAU-01 UPS-1 UPS-2 IOAU-05 TN2Critical Load Cabinet UPS Shutdown Procedure Operating Procedures UPS Start-up ProcedureEPO Emergency Power Off Procedure Transfer of load from inverter to maintenance bypass Maintenance bypass set-up proceduresTransfer of load from maintenance bypass to inverter UPS Fault Electric Owners / Technical Manual Response to UPS FailureParts Replacement UPS Component PartsFault Codes Contact Mitsubishi Electric Automation, Inc. atCode List MitsubishiINV. or Conv Inverter Overload DC circuit failure Mitsubishi Electric Automation Inc 847