Mitsubishi Electronics MUZ-GB50VA service manual Performance Curves, Indoor Unit Outdoor Unit

Page 9

8

PERFORMANCE CURVES

MUZ-GB50VA

The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions. Since operating conditions vary according to the areas where these units are installed. The following information has been provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.

(1)GUARANTEED VOLTAGE 207 ~ 253V, 50Hz

(2)AIR FLOW

Air flow should be set at MAX.

 

 

 

(3) MAIN READINGS

 

}

 

(1)

Indoor intake air wet-bulb temperature :

°C [WB]

 

(2)

Indoor outlet air wet-bulb temperature :

°C [WB]

Cooling

(3)

Outdoor intake air dry-bulb temperature :

°C [DB]

(4)

Total input:

W

}

 

(5)

Indoor intake air dry-bulb temperature :

°C [DB]

Heating

(6)

Outdoor intake air wet-bulb temperature :

°C [WB]

(7)

Total input :

W

 

 

Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.

How to measure the indoor air wet-bulb / dry-bulb temperature difference

1.Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air speed is high.

2.Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake. Cover the thermometers to prevent direct rays of the sun.

3.Check that the air filter is cleaned.

4.Open windows and doors of room.

5.Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE.

6.When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.

7.10 minutes later, measure temperature again and check that the temperature does not change.

INDOOR UNIT

OUTDOOR UNIT

Wet and dry-bulb thermometers

8-1. Capacity and input curves

Wet and dry-bulb thermometers

temperature

(:)

air Wet-bulb

difference

Indoor

 

 

MSZ-GB50VA

8.7

8.0

7.3

6.6

5.9

5.3

MUZ-GB50VA

Rated frequency 79Hz

Indo

or

in

take

air W

et-

bulb

tem

pera

ture (

:)

Outdoor intake air Dry-bulb temperature (:)

 

 

 

)

 

 

 

(:

 

 

 

perature

 

 

-bulb

tem

 

et

 

air

W

 

 

intake

 

 

 

Indoor

 

 

 

Outdoor intake air Dry-bulb temperature (:)

9

Image 9
Contents Revised EDITION-A R410A Refrigerant OBR01 ContentsMUZ-GA50VA E1 Technical ChangesSNB130FLDH SNB130FLDH1Accessories SpecificationPart Names and Functions MUZ-GB50VASpecifications and rating conditions of main electric parts Band Octave Noise Criteria CurvesMUZ-GB50VA Outdoor Unit Outlines and DimensionsOutdoor Unit MUZ-GB50VA Wiring DiagramUnitmm Refrigerant System DiagramPerformance Curves Indoor Unit Outdoor UnitCapacity and input curves MUZ-GB50VA Test RUN Operation How to operate fixed-frequency operationCool operation Performance Data Cool operation Rated frequency 79Hz MSZ-GB50VA MUZ-GB50VAOutdoor SHC SHF InputOutdoor DB Performance Data Heat operation Actuator ControlOutdoor fan motor control R.V. coil controlRelation between main sensor and actuator MUZ-GB50 TroubleshootingOFF Failure mode recall functionOperational procedure Outdoor unit failure mode table Time flash Communication error Lighting Indicator Instruction of troubleshootingOperation EmergencyOperate Lightning Twice Outdoor power system Troubleshooting check table MUZ-GB50VAOnce Lighting RED BLK BLK WHT Trouble criterion of main parts MUZ-GB50VAWHT RED RED ORNTroubleshooting flow How to check inverter/ compressorCheck of outdoor thermistors Check of R.V. coil When heating operation does not workCheck of outdoor fan motor Check of power supplyCheck of LEV Check of current-limiting resistorParts side Electromagnetic noise enters into TV sets or radios Discharge temperature thermistor RT62 Noise filter P.C. board CN2 Outdoor power boardCN3 CN5Disassembly Instructions MUZ-GB50VA Outdoor Unit Operating Procedure PhotosRemoving the cabinet Photo Removing R.V. coil Operating Procedure PhotosRemoving outdoor fan motor Photo Ture thermistor and ambient temperature thermistorRemoving the reactor Removing the compressor and 4-way valve PhotoRoHS Parts List RoHS compliant MUZ-GB MUZ-GB50 MUZ-GB50VA Accessory