Nokia DNT2Mi-fp Management, Timing source, Q1 transmission speed Q1 6,1,1, Q1 address Q1 6,1,2

Page 28

DNT2Mi-fp Data Network Terminal User manual

If errors were found during the power-up test, more information on this can be found in the Self test menu (Q1: 5,4,0).

6.1Management

DNT2Mi-fp can be managed through the line connection or local management port LMI.

The following items need to be checked:

Q1 transmission speed (Q1: 6,1,1)

The Q1 transmission speed needs to be set to match the system management speed.

Q1 address (Q1: 6,1,2)

The equipment needs a Q1 address to be visible in the NMS systems. You must give a unique address to each equipment.

You can also enter a name for the equipment by using the command 4,7,2,1

Q1 management via line (Q1: 6,1,3)

The routing of the management must be defined to correspond with the system.

Note

The address setting has the following restrictions:

The address 4095 must not be given if the equipment is connected to an NMS bus. This address is a common (broadcast) address.

The address 4094 is reserved for PC-TMC/STE use (general address for the PC interface unit).

The address 0 is reserved for PC-TMC/STE use (default address for the PC interface unit).

6.2Timing source

Before connecting DNT2Mi to a network, you need to know how the network is timed.

DNT2Mi-fp can receive timing information through the Line or Port interfaces.

28 (60)

© Nokia Corporation

DN0445814

 

Nokia Proprietary and Confidential

Issue 2-0 en

Image 28
Contents DNT2Mi-fp Data Network Terminal Product code Product versionsContents Page Document Date Comment Product collection and disposal within the European UnionPage About this document Page PDHLocal Network Exchange Introduction to DNT2Mi-fpDNT2Mi-fp BTS Shdsl Alarm LED Power LEDFront view Page Wall mounting Rear panelFastener Line interface Power supplyPin modular jack, RJ-11 DSL Line Selection of Power Supply option is done by strapping Strapping instruction for Power Supply48V DC Supply Remote Power Supply defaultExternal AC/DC converter Supply Removal instruction Remote power feed through line 48VDC Converter Earthing bar Mm2 wire 110/230 V AC704/2M Pin modular jack Pin Data interface RJ-45 Terminal interfaceSymmetrical G.704/2M interface Page Use of signal 108 when using Mste ManagementCode Name Connector type Length DIP Switch LMI Interface type selection107 HiZ Tx b OUT 108 109 Tx a OUT 103 Rx b 104 DIP-switch Q1 management busPage Automatic power-up test CommissioningManagement Timing sourceQ1 transmission speed Q1 6,1,1 Q1 address Q1 6,1,2Power backoff Q1 6,3,6 Line settingsLine interface Q1 6,3,3 Port settings Protection settingsMeasurements After the testsPage Getting general information MaintenanceS65692.01 A0 Serial number 4H0415 Monitoring alarms DNT2Mi AS Line No incoming signalDNT2Mi-fp Code Severity Q1 messageSB 1, Port TestingSB 2, Line Port Interface Line Q1 management Automatic controllPort Interface Line Interface Checking measurements and statistics Measurements via Q1Monitoring a line DNT2Mi-fp statisticsInformation Abbreviation Description And/or ratio Statistics values via Q1System counters Q1 8,3 Technical specifications DNT2Mi-fp dimensionsEnvironmental and mechanical Line interface in accordance with ITU-T G.991.2Data interface Data lead timeData lead-time ACL2i to DNT2Mi-fp = 3 to 32 192 kbit/ to 2048 kbit/sPower consumption DNT2Mi-fp power supplyPower supply external AC/DC converter Safety DC power supplyRemote power supply Mean time between failure MtbfPage Factory settings Service settingsLine interface settings Data interface settings E1Alarm limits Fault display Identifications Controls Settings Measurements StatisticsUser priviliges GeneralMain Q1 menu structure Identifications menu 2,1 Controls menu Settings menu structure 2,1Settings menu structure 3,1 1003,1,2 3,1,42,1..5 Give filling value 0 orMeasurements menu structure Statistics menu structure 3,1..2,0 DNT-fp privileges 10,110,3 10,4