Nokia DNT2Mi-fp user manual Main Q1 menu structure

Page 48

DNT2Mi-fp Data Network Terminal User manual

1 Fault display

2 Local alarm cancel *)

3 Reset local cancel *)

4Identifications

5Controls

6Settings

7Measurements

8Statistics

9Testing *)

10User privileges

11Miscellaneous *)

*) not implemented

DNT-fp Identifications:

0Display

1Eq type

2Eq name

44 Installation info

5 HW version

6 SW version

7 Modify

8 Serial number

DNT-fp controls:

0 Display

51 All test loops off

2Port test loop

3Line test loop

4Self test

DNT-fp settings:

0Display

61 Service options

2Timing source

3Line settings

4Port settings

7Load factory settings

DNT-fp measurements:

0Display all

1Noise margins

72 Rx levels

3Tx levels

4Attenuations

5Supply voltage

6Temperature

 

DNT-fp statistics:

8

1

Port statistics

2

Line statistics

 

 

3

System counters

99 Reset all statistics

DNT-fp privileges:

101 Password for privileges

3 Cancel privileges

4 Setting parameters

Figure 22. Main Q1 menu structure

48 (60)

© Nokia Corporation

DN0445814

 

Nokia Proprietary and Confidential

Issue 2-0 en

Image 48
Contents DNT2Mi-fp Data Network Terminal Product code Product versionsContents Page Document Date Comment Product collection and disposal within the European UnionPage About this document Page Introduction to DNT2Mi-fp PDHLocal Network ExchangeDNT2Mi-fp BTS Shdsl Power LED Alarm LEDFront view Page Rear panel Wall mountingFastener Power supply Line interfacePin modular jack, RJ-11 DSL Line Selection of Power Supply option is done by strapping Strapping instruction for Power SupplyRemote Power Supply default 48V DC SupplyExternal AC/DC converter Supply Removal instruction Remote power feed through line 48VDC Converter Earthing bar Mm2 wire 110/230 V ACTerminal interface 704/2M Pin modular jack Pin Data interface RJ-45Symmetrical G.704/2M interface Page Use of signal 108 when using Mste ManagementDIP Switch LMI Interface type selection Code Name Connector type Length107 HiZ Tx b OUT 108 109 Tx a OUT 103 Rx b 104 DIP-switch Q1 management busPage Automatic power-up test CommissioningManagement Timing sourceQ1 transmission speed Q1 6,1,1 Q1 address Q1 6,1,2Line settings Power backoff Q1 6,3,6Line interface Q1 6,3,3 Port settings Protection settingsMeasurements After the testsPage Maintenance Getting general informationS65692.01 A0 Serial number 4H0415 Monitoring alarms DNT2Mi AS Line No incoming signalDNT2Mi-fp Code Severity Q1 messageTesting SB 1, PortSB 2, Line Q1 management Automatic controll Port Interface LinePort Interface Line Interface Checking measurements and statistics Measurements via Q1Monitoring a line DNT2Mi-fp statisticsStatistics values via Q1 Information Abbreviation Description And/or ratioSystem counters Q1 8,3 Technical specifications DNT2Mi-fp dimensionsEnvironmental and mechanical Line interface in accordance with ITU-T G.991.2Data interface Data lead timeData lead-time ACL2i to DNT2Mi-fp = 3 to 32 192 kbit/ to 2048 kbit/sDNT2Mi-fp power supply Power consumptionPower supply external AC/DC converter Safety DC power supplyRemote power supply Mean time between failure MtbfPage Factory settings Service settingsLine interface settings Data interface settings E1Alarm limits Fault display Identifications Controls Settings Measurements StatisticsUser priviliges GeneralMain Q1 menu structure Identifications menu 2,1 Controls menu Settings menu structure 2,1Settings menu structure 3,1 1003,1,2 3,1,42,1..5 Give filling value 0 orMeasurements menu structure Statistics menu structure 3,1..2,0 DNT-fp privileges 10,110,3 10,4