Line alarms (Q1: 6,3,8 and 6,3,9)
The BER alarm limit and alarm severity have to be checked.
6.4Port settings
You have to check the following items:
Port framing (Q1: 6,4,1)
Check that the 2M data interface settings are compatible with the equipment they are connected to.
No frame (Q1: 6,4,1,1)
Alternative if full 2M is needed and no framing is required. Port statistics is not available. Only UAT is calculated if there is no G.703 signal present at the port.
Basic frame of CRC multiframe (Q1: 6,4,1,2 or 6,4,1,3)
Alternative if fractinal 2M is needed. In this case payload rate is n*64 (n = 1 to
31)and one time slot is reserved for framing. Frame is terminated at
Monitoring Basic frame or CRC multiframe (Q1: 6,4,1,4 or 6,4,1,5)
Alternative if fractinal 2M is needed. In this case payload rate is n*64 (n = 1 to
31)and one time slot is reserved for framing. Frame is not terminated at
Port alarms (Q1: 6,4,8 and 6,3,9)
The BER alarm limit and alarm severity have to be checked.
6.5Protection settings
Password (Q1: 10,1 and 10,4)
If password is required (Q1: 10,4,2,2) and correct password has given (Q1: 10,1,[password] ), then the Q1 user has privileges to make configurations. Privileges time out is defined by Q1 menu 10,4,1 (1 to 1000 min).