Nokia user manual Technical specifications, DNT2Mi-fp dimensions, Environmental and mechanical

Page 39

Technical specifications

8 Technical specifications

Table 3. DNT2Mi-fp dimensions

Width

Height

Depth

Weight

56mm

173mm

138mm

510g

Table 4. Environmental and mechanical

Storage

ETSI ETS 300 019-2-1 class 1.2

 

 

Operation

ETSI ETS 300 019-2-3 class 3.2

 

 

Transportation

ETSI ETS 300 019-2-2 class 2.3

 

 

Table 5.

Line interface (in accordance with ITU-T G.991.2

 

Recommendation)

 

 

 

 

Connector

 

RJ-11

 

 

 

Line type

 

2 – wire or 4 – wire

 

 

Nominal impedance

135 ohms

 

 

 

Line code

 

TC-PAM

 

 

Tx power (0 dB power backoff)

11,5 dBm @ 135 ohm (192 and 256

 

 

kbit/s)

 

 

13,5 dBm @ 135 ohm (320 to 1984

 

 

kbit/s)

 

 

14,5 dBm @ 135 ohm (2048 kbit/s)

 

 

Signal bandwidth

0...300 kHz (2048 kbit/s, 2-w, -3 dB)

 

 

Line interface 192 kbit/s to 2048 kbit/s (n x 64 bit/s)

 

 

 

DN0445814

© Nokia Corporation

39 (60)

Issue 2-0 en

Nokia Proprietary and Confidential

 

Image 39
Contents DNT2Mi-fp Data Network Terminal Product versions Product codeContents Page Product collection and disposal within the European Union Document Date CommentPage About this document Page Introduction to DNT2Mi-fp PDHLocal Network ExchangeDNT2Mi-fp BTS Shdsl Power LED Alarm LEDFront view Page Rear panel Wall mountingFastener Power supply Line interfacePin modular jack, RJ-11 DSL Line Strapping instruction for Power Supply Selection of Power Supply option is done by strappingRemote Power Supply default 48V DC SupplyExternal AC/DC converter Supply Removal instruction Remote power feed through line 48VDC 110/230 V AC Converter Earthing bar Mm2 wireTerminal interface 704/2M Pin modular jack Pin Data interface RJ-45Symmetrical G.704/2M interface Page Management Use of signal 108 when using MsteDIP Switch LMI Interface type selection Code Name Connector type Length107 HiZ Tx b OUT 108 109 Tx a OUT 103 Rx b 104 Q1 management bus DIP-switchPage Commissioning Automatic power-up testQ1 address Q1 6,1,2 ManagementTiming source Q1 transmission speed Q1 6,1,1Line settings Power backoff Q1 6,3,6Line interface Q1 6,3,3 Protection settings Port settingsAfter the tests MeasurementsPage Maintenance Getting general informationS65692.01 A0 Serial number 4H0415 Code Severity Q1 message Monitoring alarmsDNT2Mi AS Line No incoming signal DNT2Mi-fpTesting SB 1, PortSB 2, Line Q1 management Automatic controll Port Interface Line Port Interface Line Interface DNT2Mi-fp statistics Checking measurements and statisticsMeasurements via Q1 Monitoring a lineStatistics values via Q1 Information Abbreviation Description And/or ratioSystem counters Q1 8,3 Line interface in accordance with ITU-T G.991.2 Technical specificationsDNT2Mi-fp dimensions Environmental and mechanicalData lead time Data interface= 3 to 32 192 kbit/ to 2048 kbit/s Data lead-time ACL2i to DNT2Mi-fpDNT2Mi-fp power supply Power consumptionPower supply external AC/DC converter Mean time between failure Mtbf SafetyDC power supply Remote power supplyPage Data interface settings E1 Factory settingsService settings Line interface settingsAlarm limits General Fault displayIdentifications Controls Settings Measurements Statistics User priviligesMain Q1 menu structure Identifications menu 2,1 Controls menu 2,1 Settings menu structureSettings menu structure 3,1,4 3,1100 3,1,2Give filling value 0 or 2,1..5Measurements menu structure Statistics menu structure 3,1..2,0 10,4 DNT-fp privileges10,1 10,3