Fisher FB1000-2 manual Getting Started, Using the Power Supply

Page 6

Getting Started

Select a location that allows for 3" clearance behind the power supply, and comfortable reach of the front panel controls and cell connections. Do not block the vented area of the case - on the front bottom of the unit, or the fan area at the rear. Connect the power supply to a 3-prong grounded AC outlet, using the AC cord provided with the unit only. Connect the electrophoresis apparatus to the power supply, making sure to match the red positive lead to the red positive jack, and the black negative lead to the black negative jack. Similarly, connect a second or more electrophoresis apparatus to the power supply if you plan to run more than one in parallel. Attach a temperature probe to the FB1000 rear located connector and the electrophoresis apparatus if you intend to perform temperature monitoring for a run. Power the unit on using the AC power switch located at the rear of the unit, next to the AC line cord entry.

Function keys

black negative jacks

Exit key

 

Clear key

 

black negative jacks

red positive jacks

Run key

Stop key

Pause key

red positive jacks

gray ON/OFF key

Figure 1. Front Panel Controls

Using the Power Supply

Press the dark gray key on the front of the unit to enable/disable the control logic. The LCD display will illuminate and allow selection of MANUAL or PROGRAM mode of operation as well as enable/disable automatic power-fail restart. Toggle automatic power-fail restart by pressing the topmost function key to the right of the display. Select MANUAL or PROGRAM mode using the function keys to the right of the display (see Programming section for programming mode description). In manual mode, the FB1000 preserves the constant setpoint each time you start a run. The constant parameter is saved independently for each mode; constant voltage, current, and power.

To change the control mode, press the Exit key. From the resulting screen, select the new constant parameter using the function keys to the right of the display.

FB1000-2 MANUAL

Page 5

7608177 Rev. A 8/9/02

Image 6
Contents FB1000-2 Electrophoresis Power Supply Operator’s ManualFisher Biotech FB1000 Electrophoresis Power Supply Table of ContentsSafety Considerations Unpacking the Power Supply IntroductionDC output Power SpecificationsAC input Power EnvironmentalUsing the Power Supply Getting StartedConstant Power Operations Constant Voltage OperationsConstant Current Operations Volt-Hour Operations Automatic Power-fail RestartTimed Operations ProgrammingFB1000-2 Manual Method 1 1/2 Next CleaningMethod Next Steps Prev Edit 100V / 200mA PrevTroubleshooting and Error Indications Replacing a fuseFB1000 Warranty Statement Replacement PartsCompliance Table des matières Considérations de sécurité Déballage de l’alimentation électrique CaractéristiquesEnvironnement SpécificationsCourant d’entrée CA Courant de sortie CCMise en route Utilisation de l’alimentation électriqueOpérations à tension constante Opérations à intensité constanteOpérations à puissance constante Opérations à durée déterminéeOpérations en volts-heures Redémarrage automatique en cas de coupure de courant ProgrammationFB1000-2 Manual Steps Prev NettoyageMethod Next 150W AddRemplacement d’un fusible Dépannage et indications d’erreurPièces de rechange Garantie du FB1000Conformité Fisher Scientific Park Lane Pittsburgh, PA 15275 USAFisher Biotech FB1000 Elektrophorese-Netzteil InhaltsverzeichnisSicherheitstechnische Hinweise Einführung Auspacken des NetzteilsUmfeldbedingungen Technische DatenNetzeingangsleistung GleichstromausgangsleistungEinstieg Verwenden des NetzteilsBetrieb bei Dauerspannung Betrieb bei DauerstromBetrieb bei Dauerleistung Zeitgesteuerter BetriebVoltstundenbetrieb Automatischer Neustart bei Stromausfall ProgrammierungMethod 1 1/2 Next 100V / 200mA Prev 150W Add 010 Edit Reinigung 150W Hinzuf 010 BearbeitenFehlersuche und Fehlermeldung Auswechseln einer SicherungFB1000 Garantieerklärung KompatibilitätErsatzteile Contenido Consideraciones de seguridad Introducción Desembalaje de la fuente de alimentaciónMedioambientales EspecificacionesPotencia de entrada de CA Potencia de salida de CCPara empezar Uso de la fuente de alimentaciónOperaciones a voltaje constante Operaciones a corriente constanteOperaciones en voltios-hora Operaciones a potencia constanteOperaciones temporizadas Reinicio automático tras un fallo en la alimentaciónProgramación FB1000-2 Manual Pasos Prev LimpiezaMétodo Next Método 1 1/2 NextDiagnóstico e indicaciones de error Condición y posible soluciónDeclaración de garantía del FB1000 Conformidad Conformidad EMC Compatibilidad electromagnéticaPiezas de repuesto Fisher Scientific Park Lane Pittsburgh, PA 15275, EE.UUFB1000-2 Electrophoresis Power Supply Part No Rev a