Fisher FB1000-2 manual Introduction, Unpacking the Power Supply

Page 4

Introduction

Thank you for selecting a Fisher Scientific FB1000 Electrophoresis power supply. This manual describes the operation of the FB1000. The power supply that you have purchased is the most productive and easy-to-use unit available anywhere. This manual should answer any questions that might arise in operating your power supply; however, don't hesitate to call our Fisher Lab Equipment Technical Support Hotline at 1-800-943-2006 or 1-800-926-0505 if you need any assistance.

The FB1000 power supply is designed to provide constant voltage, current, or power in both Manual and Programmed modes of operation commonly used in electrophoresis applications. One to four sets of electrophoresis cells can be connected in parallel and run simultaneously. The FB1000 can deliver up to 250W of total output power. When operating in any constant mode, the power supply automatically limits the other parameters to either the power supply maximum, or a lower limit if set by the user. If any non-constant limit is reached, the power supply will automatically switch control modes, controlling the limit parameter. In this way, the FB1000 protects your electrophoresis cells from damaging over power conditions. The FB1000 power supply also provides for timed and volt-hour operation in all control modes, and allows an automatic completion in the event of a power loss if enabled.

Features

5-1000V, adjustable in 1 volt steps

1-500mA, adjustable in 1mA steps

1-250W, adjustable in 1W steps

0-90C, adjustable in 1degree C steps

Automatic control mode crossover

0-99 hour 59 minute timed run

0-9999 volt-hour timed run

Automatic restart if loss of AC power (if enabled)

Large LCD display

Unpacking the Power Supply

When unpacking your FB1000 power supply, be sure you have received the following items.

FB1000 unit

AC line cord

This manual

Inspect your equipment and packaging material for signs of damage. Damage to the shipping container may indicate rough handling which could cause internal damage to the power supply. If you suspect shipping damage to the power supply, contact your carrier for instructions on filing a claim. If you are missing any of the above items, contact your supplier for instructions.

FB1000-2 MANUAL

Page 3

7608177 Rev. A 8/9/02

Image 4
Contents FB1000-2 Electrophoresis Power Supply Operator’s ManualFisher Biotech FB1000 Electrophoresis Power Supply Table of ContentsSafety Considerations Unpacking the Power Supply IntroductionSpecifications AC input PowerDC output Power EnvironmentalUsing the Power Supply Getting StartedConstant Voltage Operations Constant Power OperationsConstant Current Operations Automatic Power-fail Restart Timed OperationsVolt-Hour Operations ProgrammingFB1000-2 Manual Cleaning Method Next Steps Prev EditMethod 1 1/2 Next 100V / 200mA PrevTroubleshooting and Error Indications Replacing a fuseReplacement Parts FB1000 Warranty StatementCompliance Table des matières Considérations de sécurité Déballage de l’alimentation électrique CaractéristiquesSpécifications Courant d’entrée CAEnvironnement Courant de sortie CCMise en route Utilisation de l’alimentation électriqueOpérations à tension constante Opérations à intensité constanteOpérations à durée déterminée Opérations à puissance constanteOpérations en volts-heures Redémarrage automatique en cas de coupure de courant ProgrammationFB1000-2 Manual Nettoyage Method NextSteps Prev 150W AddRemplacement d’un fusible Dépannage et indications d’erreurGarantie du FB1000 ConformitéPièces de rechange Fisher Scientific Park Lane Pittsburgh, PA 15275 USAFisher Biotech FB1000 Elektrophorese-Netzteil InhaltsverzeichnisSicherheitstechnische Hinweise Einführung Auspacken des NetzteilsTechnische Daten NetzeingangsleistungUmfeldbedingungen GleichstromausgangsleistungEinstieg Verwenden des NetzteilsBetrieb bei Dauerspannung Betrieb bei DauerstromZeitgesteuerter Betrieb Betrieb bei DauerleistungVoltstundenbetrieb Automatischer Neustart bei Stromausfall ProgrammierungMethod 1 1/2 Next 100V / 200mA Prev 150W Add 010 Edit Reinigung 150W Hinzuf 010 BearbeitenFehlersuche und Fehlermeldung Auswechseln einer SicherungKompatibilität FB1000 GarantieerklärungErsatzteile Contenido Consideraciones de seguridad Introducción Desembalaje de la fuente de alimentaciónEspecificaciones Potencia de entrada de CAMedioambientales Potencia de salida de CCPara empezar Uso de la fuente de alimentaciónOperaciones a voltaje constante Operaciones a corriente constanteOperaciones a potencia constante Operaciones temporizadasOperaciones en voltios-hora Reinicio automático tras un fallo en la alimentaciónProgramación FB1000-2 Manual Limpieza Método NextPasos Prev Método 1 1/2 NextDiagnóstico e indicaciones de error Condición y posible soluciónDeclaración de garantía del FB1000 Conformidad Conformidad EMC Compatibilidad electromagnéticaPiezas de repuesto Fisher Scientific Park Lane Pittsburgh, PA 15275, EE.UUFB1000-2 Electrophoresis Power Supply Part No Rev a