| • If the counter value set by N5 goes out of the counter operation |
| range, it will be forced to convert to the minimum by GS c. |
| With counting down |
| • If the counting down reaches the value less than the minimum, |
| it will be resumed with the maximum. |
| • If the counter value set by N5 goes out of the counter operation |
| range, it will be forced to convert to the maximum by G3 c. |
[Default] | N1 = 1, N2 = 65535, N3 = 1, N5 =1 |
[Reference] | GS CO, GS Cl, GS C2, GS c |
GS H n
[Name] | Select printing position of HRI characters | ||||||
[Format] | <1D>H<48>H<n> |
|
|
|
|
| |
[Range] | O ≤ n ≤ 3 |
|
|
|
|
|
|
[Description] | Selects the printing position of HRI characters when printing a bar | ||||||
| code. |
|
|
|
|
|
|
| • n selects the printing position from the following table. | ||||||
|
|
|
|
| |||
| n |
| Printing position |
| |||
|
|
|
|
|
| ||
| 0 | Not printed |
|
|
| ||
|
|
|
|
|
|
| |
| 1 | Above | the | bar | code |
|
|
|
|
|
|
|
|
| |
| 2 | Below | the | bar | code |
|
|
|
|
|
|
| |||
| 3 | Both above and below the bar code |
| ||||
| • HRI means Human Readable Interpretation. | ||||||
[Notes] | • HRI characters are printed using the font specified by GS f. | ||||||
[Default] | n = 0 |
|
|
|
|
|
|
[Reference] | GS f |
|
|
|
|
|
|
GS c
[Name] | Print counter |
[Format] | <1D>H<63>H |
[Description] | Prints the serial counter. |
| • Sets the current counter value in the print buffer as a print data |
| (character string) and then counts up or down the counter based |
| on the count mode set. |
50