Windows 98/Me/2000

To scan directly into an application using the Button Manager on Windows 98, Windows Me and Windows 2000. Set the Event Manager properties to send only to Button Manager as shown below.

1Click the "Start" button, select "Control Panel" from "Settings", and open "Scanners and Cameras" in start menu.

In Windows Me, it occasionally happens that the "Scanners and Cameras" icon does not appear immediately after installation of the MFP driver is completed. If the icon does not appear, click "View all Control Panel options" in the Control Panel and display the "Scanner and Cameras" icon.

2

3

Select "AL-xxxx" (where xxxx is the model name of your unit) and click the "Properties" button.

In Windows Me,right click "AL-xxxx" (where xxxx is the model name of your

4

unit) and click the "Properties" in the menu that appears.

 

 

In the "Properties" screen, click the

 

 

SHARP AL-xxxx Properties

 

"Events" tab.

SHARP AL-xxxx

4Click the "Scanner event" button and select "ScanMenu SC1" from the pull-down menu. Select "Button Manager (SHARP Personal MFP Series)" in "Send to this application" and click "Apply".

If other application are shown, deselect the checkboxes for the other applications and leave only the Button Manager checkbox selected.

SHARP AL-xxxx Properties

SHARP AL-xxxx

5Repeat step 4 to set "ScanMenu SC2" through "ScanMenu SC6".

Click the "Select an Event" and select "ScanMenu SC2" from the pull-down menu. Select "Button Manager (SHARP Personal MFP Series)" in "Start this program" and click "Apply". Do the same for each ScanMenu through "Scanmenu SC6".

When the settings have been completed, click the "OK" button to close the screen. When the settings have been completed in Windows, start the Button Manager. Adjust detailed settings and then scan an image from the unit. For the procedures for starting Button Manager and adjusting settings, see "Scan Parameter Settings Dialog Box (p.36)".

35

Image 37
Contents AL-1045 AL-1255 AL-1456 AL-1555 Varoitus Do not install your unit in areas that are Important points when selecting an installation siteBe sure to allow the required space around the machine For servicing and proper ventilationTrademark acknowledgements Safety precautionsContents Online manual Using the ManualsConventions used in this manual and online manual Original cover Part NamesInterface Operation Panel Original to copy key and indicators AL-1555Setup Procedure Setting UP the UnitPreparing the Unit for Installation Checking Packed Components and AccessoriesLockUnlock Release the scan head locking switchInstalling the TD Cartridge Page About the scan head Power onInitial settings of operation panel Power off methodsAL-1555 only Paper Type of paper Type of media Size Weight FeedingLoading the Paper Tray Gently push the paper tray back into the unit Open the multi-bypass tray and extend the tray Multi-bypass tray AL-1555Press the tray select key to select the multi-bypass tray Using printer mode Using copy modeSingle bypass AL-1045/AL-1255/AL-1456 Hardware and Software Requirements Software for the Sharp Personal MFP SeriesMFP driver SharpdeskFlow of installation Before InstallationOperating Interface Reference pages for how to install MFP Driver ButtonInstalling onto Windows XP USB/parallel interface Installing the SoftwareDouble-click the Setup icon Button Manager installer will start Setup program will start to copy the files Begin installation of the printer driver Begin installation of the scanner driverInstalling onto Windows 98/Me/2000 USB interface Copying files for MFP driver installation Connect the USB interface cable. p.45 Click the Close button whenWindows 95/NT Establish the printer settings and click the Next button Connect the parallel interface cable Start indicator Indicators on the Operation PanelOn Line indicator Power save indicatorOpening the printer driver from the start menu Using the Printer ModeClick the Printing Preferences button in the General tab Tray How to printUsing the Button Manager Using the Scanner ModeSetting up the Button Manager Properties screen, click Windows 98/Me/2000Events tab Scan Parameter Settings Dialog Box Flow of the Button Manager setting Press the Scanner key Using the Scanner key to begin scanningPress the start key Opening the scanner driver and scanning from your computerApplication Application launched Number Button Select Sharp Personal MFP Series, and click the SelectClick here Scanning with the Scanner and Camera Wizard in Windows XP For information on the settings, seeSelect a name, format, and folder for the scanned image Click Finish in the screen that appearsClick the to read the online manual HOW to USE the Online ManualInstalling Acrobat Reader Using Other Installed Drivers Connecting the USB interface cable Connecting the Interface CableConnecting the parallel interface cable Obtain a shielded USB interface cableCopy Flow Scan Once / Print ManyStart copying Using the original table Original PlacementAbout interrupt copying Stream feeding mode Using the SPF/RSPFOriginal feeder tray Exposure adjustment Exposure ADJUSTMENT/PHOTO CopyingSET the Copy Quantity Automatic exposure adjustment Set the reduction/enlargement ratio REDUCTION/ENLARGEMENT/ZOOMTo select a zoom ratio Two sided copying About the Special Functions of the AL-1555Selecting the tray How to select the trayDescription of Special Functions Toner Save ModeFeeding mode and resolution of Auto & Manual mode Setting the power save modes, auto clear time, streamCanceled as desired User ProgramsDisplaying Total Number of Copies Program Mode ParametersGently pull the TD cartridge out TD Cartridge ReplacementWhile pressing the lock release Button Lock release buttonGently pull the cartridge out. Dispose Drum Cartridge ReplacementCabinet Cleaning the UnitOriginal table and the back side of the original cover/SPF Transfer charger Troubleshooting Troubleshooting the UnitIndication Cause and remedy Status IndicatorsPaper feed area. p.66 Misfeed RemovalMisfeed in the paper feed area. p.64 Lower the fusing unit release Misfeed in the fusing areaMisfeed in the paper feed area LeverMisfeed in the transport area Lower the fusing unit release leverOpen the front cover Rotate the feeding roller Direction of the arrowMisfeed in the SPF/RSPF Misfeed in the lower paper feed area AL-1456/AL-1555AL-1555 Appendix SpecificationsSharp GDI Supply list About Supplies and OptionsInterface cable Parallel interface cableMoving instructions Moving and Storing the UnitProper storage Store the supplies in a location that isDark key IndexMFP driver Index by Purpose Software License Limited Warranty on Media Page Page Page Page Page Page Page Page GREEN-AND-YELLOW Sharp Corporation