OPERATING INSTRUCTIONS

STEP 3

Connecting the Remote Control Cable

4

5

6

7

Insert the protective cover into the lock housing during use of the device.

Check the control cable and source assembly connectors using the NO GO gauge according to the daily inspection section.

Remove the protective rubber cap from the remote control connector.

IMPORTANT WARNING

The control cable connector is a made from hardened steel and should never be left unprotected or forced into connection with the source assembly as this could damage the connector overtime leading to possible breakage during use.

ALWAYS use the protective end-cover when remote controls are not connected to the exposure device and ALWAYS manually move the sleeve of the female connector of the source assembly to the OPEN position when connecting and disconnecting the control cable from the source assembly.

Slide the remote control connector assembly’s collar back and open the jaws to expose the male portion of the control cable connector (i.e. the ball-end on the control cable connector).

Press back the spring-loaded locking pin of the source assembly connector with a thumb-nail and engage the male and female portions of the connectors.

Release the locking pin of the source assembly connector and check that the connection is secure.

Use the NO GO gauge to check the gap between the joined connectors during the daily inspection.

2.6

Image 17
Contents MAN-027-May Operating and Maintenance ManualTime Page Front View Exposure Device Description Model 880 Delta authorized contents Standard Source AssemblyModel 880 Sigma authorized contents ApplicationsModel 880 Omega authorized contents Model 880 Elite authorized contentsSource output Selected attenuation dataSource Guide Tube Extension Control Specifications Complete Remote Control AssembliesSource Guide Tube with source stop Weight of Exposure Device Type BU Certification Exposure Device Specifications Manufacturer LengthWeight of Depleted Uranium Shield Primary Application WidthDevice Operating Temperature Range Maintenance RequirementsSource Assembly ConstructionWarranty and Limitation of Liability Restricted Area Job site safety precautions InstrumentsDistance ShieldingSource Guide Tube projection sheath Layout Exposure Device SurveySimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Locking the Exposure Device RetractingConfirmatory Survey Source guide tubes Dismantling equipment Remote control unitSurveying StorageIntroduction Operational Features Source AssemblyExposure Device Source assembly and remote control cable connectorsDaily Inspection Instructions Exposure Mode Transit ModeDaily Inspection of the Exposure Device Daily Inspection of the SystemDaily Inspection of the Source Guide Tubes Daily Inspection of the Remote ControlsImportant Warning Remote Control InspectionControl Cable Inspection Control Conduit InspectionImportant Reminder Maintenance Instructions Radiographic Exposure Device Routine Quarterly Maintenance Requirements Remote ControlsMisconnect Test Annual Maintenance Requirements Routine Quarterly Maintenance RecordsLeak Test for Depleted Uranium DU Leak Testing Leak Test of the Radioactive Sealed SourceAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Remote Control Maintenance Requirements Annual Maintenance for the Remote ControlsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Source Guide Tube Maintenance Quarterly and Annual Maintenance for Source Guide TubesMaintenance Instructions Considerations of Safety Class a Items Annual Maintenance RecordsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Sample Transportation Instructions Transport PackageReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Alarm ratemeter Area alarmApparatus for industrial gamma radiography Automatic securing mechanismExposure head Remote controlLocked position Maximum ratingWorking position Source holderSource changers Training EmergenciesUnited States Regulations Access to Restricted AreasEU Regulations Personnel MonitoringDisposal Abc