Sigma projetor manual 1Unlocking

Page 19

OPERATING INSTRUCTIONS

STEP 4

Projecting and Retracting the Source Assembly

1Unlocking

If engaged, unlock the exposure device’s plunger lock with the key.

2

Rotate the selector ring to the OPERATE position.

 

Ensure there is no tension/force in either direction on the

 

control cable.

 

 

 

Push the lock slide GREEN MARKING laterally from left to

3

 

right (as seen behind the projector) until the lock slide

RED MARKING fully appears on the right side of the selector ring and you feel or hear the sleeve snap into the slide.

When the GREEN MARKING is visible, the source assembly is locked into the secured position within the exposure device.

 

When the RED MARKING is visible, the source assembly

4

 

is free to be projected from, and retracted to, the projector.

Ensure all personnel leave the immediate area.

Got to the remote control crank.

If an odometer is fitted, adjust the reset knob to read zero.

The source assembly can now be projected.

2.8

Image 19
Contents MAN-027-May Operating and Maintenance ManualTime Page Front View Exposure Device Description Applications Standard Source AssemblyModel 880 Delta authorized contents Model 880 Sigma authorized contentsSelected attenuation data Model 880 Elite authorized contentsModel 880 Omega authorized contents Source outputSource Guide Tube with source stop Control Specifications Complete Remote Control AssembliesSource Guide Tube Extension Primary Application Width Exposure Device Specifications Manufacturer LengthWeight of Exposure Device Type BU Certification Weight of Depleted Uranium ShieldConstruction Maintenance RequirementsDevice Operating Temperature Range Source AssemblyWarranty and Limitation of Liability Shielding Job site safety precautions InstrumentsRestricted Area DistanceSource Guide Tube projection sheath Layout Exposure Device SurveySimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Confirmatory Survey RetractingLocking the Exposure Device Storage Dismantling equipment Remote control unitSource guide tubes SurveyingIntroduction Operational Features Source AssemblyExposure Device Source assembly and remote control cable connectorsDaily Inspection Instructions Exposure Mode Transit ModeDaily Inspection of the Exposure Device Daily Inspection of the SystemDaily Inspection of the Source Guide Tubes Daily Inspection of the Remote ControlsImportant Warning Remote Control InspectionControl Cable Inspection Control Conduit InspectionImportant Reminder Maintenance Instructions Radiographic Exposure Device Routine Quarterly Maintenance Requirements Remote ControlsMisconnect Test Annual Maintenance Requirements Routine Quarterly Maintenance RecordsLeak Test for Depleted Uranium DU Leak Testing Leak Test of the Radioactive Sealed SourceAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Remote Control Maintenance Requirements Annual Maintenance for the Remote ControlsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Source Guide Tube Maintenance Quarterly and Annual Maintenance for Source Guide TubesMaintenance Instructions Considerations of Safety Class a Items Annual Maintenance RecordsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Sample Transportation Instructions Transport PackageReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Automatic securing mechanism Area alarmAlarm ratemeter Apparatus for industrial gamma radiographyMaximum rating Remote controlExposure head Locked positionSource changers Source holderWorking position Training EmergenciesPersonnel Monitoring Access to Restricted AreasUnited States Regulations EU RegulationsDisposal Abc