OPERATING INSTRUCTIONS
STEP 4
Projecting and Retracting the Source Assembly
1Unlocking
If engaged, unlock the exposure device’s plunger lock with the key.
2 | Rotate the selector ring to the OPERATE position. |
| Ensure there is no tension/force in either direction on the |
| control cable. |
|
|
| Push the lock slide GREEN MARKING laterally from left to |
3 | |
| right (as seen behind the projector) until the lock slide |
RED MARKING fully appears on the right side of the selector ring and you feel or hear the sleeve snap into the slide.
When the GREEN MARKING is visible, the source assembly is locked into the secured position within the exposure device.
| When the RED MARKING is visible, the source assembly |
4 | |
| is free to be projected from, and retracted to, the projector. |
Ensure all personnel leave the immediate area.
Got to the remote control crank.
If an odometer is fitted, adjust the reset knob to read zero.
The source assembly can now be projected.
2.8