Sigma projetor manual Control Specifications Complete Remote Control Assemblies

Page 8

TECHNICAL SPECIFICATIONS

Note:

The total length of source guide tubes utilized must be shorter in length than the remote controls to ensure the source assembly will project into the working position.

e.g. When using 25 ft (7.6 m) remote controls, a maximum of three 7 ft (2.1 m) source guide tubes can be used with a combined length of 21 ft (6.4 m).

Conversely, when using 35 ft (10.7 m) remote controls, a maximum of four 7 ft (2.1 m) source guide tubes can be utilized.

When using 50 ft (15 m) remote controls, a maximum of six 7 ft (2.1 m) source guide tubes can be utilized. This limitation is due to the weight and friction of remote control cable length.

Control Specifications

Complete Remote Control Assemblies

Product code

Model number

Control cable length

Unit weight

TAN66425

664/25

25 ft (7.6 m)

21 lb (10 kg)

TAN66435

664/35

35 ft (10.7 m)

24 lb (11 kg)

TAN66450

664/50

50 ft (15.2 m)

27 lb (12 kg)

TAN69325

693/25

25 ft (7.6 m)

21 lb (10 kg)

TAN69335

693/35

35 ft (10.7 m)

24 lb (11 kg)

TAN69350

693/50

50 ft (15.2 m)

27 lb (27 kg)

TAN69225

692/25

25 ft (7.6 m)

21 lb (10 kg)

TAN69235

692/35

35 ft (10.7 m)

24 lb (11 kg)

TAN69250

692/50

50 ft (15.2 m)

27 lb (12 kg)

88325

883/25

25 ft (7.6 m)

 

88335

883/35

35 ft (10.7 m)

 

88350

883/50

50 ft (15.2 m)

 

Model 664 Control Storage Reel Unit Size

_____

Length

Width

Height

 

21 in (533 mm)

12 in (305 mm)

6.6 in (168 mm)

The Model 664 reel and 693 pistol grip controls are equipped with odometers. The Model 692 pistol-grip controls are not equipped with an odometer.

Source Guide Tube (with source stop)

Product Code

Model Number

Length

TAN48906

48906

7 ft (2.1 m) male 1-18 threaded fitting

48906-X

48906-X

Customer specified length

48931-7

48931-7

7 ft (2.1 m) with bayonet fitting

48931-X

48931-X

Customer specified length with bayonet fitting

95020

95020

7 ft (2.1m) male 1-18 threaded fitting

95020-X

95020-X

Customer specified length

Source Guide Tube Extension

Product Code

Model Number

Length

TAN48907

48907

7 ft (2.1 m) male/female 1-18 threaded fittings

48930-7

48930-7

7 ft (2.1 m) bayonet fitting/female 1-18

48930-X

48930-X

Customer specified length bayonet fitting/female 1-18

95021

95020

7 ft (2.1 m) male/female 1-18 threaded fittings

95021-X

95021-X

Customer specified length

NOTE: X indicates customer can order lengths other than the standard length.

1.4

Image 8
Contents Operating and Maintenance Manual MAN-027-MayTime Page Front View Exposure Device Description Standard Source Assembly Model 880 Delta authorized contentsModel 880 Sigma authorized contents ApplicationsModel 880 Elite authorized contents Model 880 Omega authorized contentsSource output Selected attenuation dataSource Guide Tube Extension Control Specifications Complete Remote Control AssembliesSource Guide Tube with source stop Exposure Device Specifications Manufacturer Length Weight of Exposure Device Type BU CertificationWeight of Depleted Uranium Shield Primary Application WidthMaintenance Requirements Device Operating Temperature RangeSource Assembly ConstructionWarranty and Limitation of Liability Job site safety precautions Instruments Restricted AreaDistance ShieldingExposure Device Survey Source Guide Tube projection sheath LayoutSimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Locking the Exposure Device RetractingConfirmatory Survey Dismantling equipment Remote control unit Source guide tubesSurveying StorageOperational Features Source Assembly IntroductionSource assembly and remote control cable connectors Exposure DeviceDaily Inspection Instructions Transit Mode Exposure ModeDaily Inspection of the System Daily Inspection of the Exposure DeviceDaily Inspection of the Remote Controls Daily Inspection of the Source Guide TubesRemote Control Inspection Important WarningControl Conduit Inspection Control Cable InspectionImportant Reminder Maintenance Instructions Routine Quarterly Maintenance Requirements Remote Controls Radiographic Exposure DeviceMisconnect Test Routine Quarterly Maintenance Records Annual Maintenance RequirementsLeak Testing Leak Test of the Radioactive Sealed Source Leak Test for Depleted Uranium DUAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Annual Maintenance for the Remote Controls Remote Control Maintenance RequirementsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Quarterly and Annual Maintenance for Source Guide Tubes Source Guide Tube MaintenanceMaintenance Instructions Annual Maintenance Records Considerations of Safety Class a ItemsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Transport Package Sample Transportation InstructionsReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Area alarm Alarm ratemeterApparatus for industrial gamma radiography Automatic securing mechanismRemote control Exposure headLocked position Maximum ratingWorking position Source holderSource changers Emergencies TrainingAccess to Restricted Areas United States RegulationsEU Regulations Personnel MonitoringDisposal Abc