SAMPLE TRANSPORTATION INSTRUCTIONS

ii.Required after 1 January 2007, the outside of the package must include the following label [IATA 10.7.4.4.3]:

6If the surface radiation level exceeds 5 µSv/hr (0.5 mRem/hr), or if there is a measurable radiation level at 1m from the surface, use the criteria of Table 1 to determine the proper shipping labels to be applied to the package.

a.Mark the outside of the outer shipping package with the proper shipping name and identification number (Radioactive Material, Low Specific Activity (LSA-I) UN2912. If the container is packaged inside a crate or other outer packaging, mark the outer package with the word ‘Overpack’.

b.Properly complete the shipping papers, indicating:

i.Proper shipping name, identification number and class (i.e. Radioactive Material, Low Specific Activity (LSA-I), Class 7, UN2912).

ii.Name of the radionuclide (i.e. depleted Uranium-238).

iii.Physical and chemical form (i.e. Solid Metal).

iv. Activity of the uranium in Becquerels or other appropriate multiples of Becquerels.

NOTE: Number of Curies x 37,000 = number of MegaBecquerels (MBq). The activity in millicuries for U-238 equals 0.16 x the shield weight in pounds (i.e. for a Model 880 Delta with a 34 lb shield, the approximate activity is 0.16 x 34 lb = 5.4 mCi).

v.Category of label applied (i.e. Radioactive Yellow II).

vi.Transport Index.

vii.USNRC identification number or DOT specification number, i.e. Model 880 Series cert:

USA/9296/B(U)-96. viii.Shipper's certification:

‘This is to certify that the above-named materials are properly classified, described, packaged, marked and labeled and are in proper condition for transport according to the applicable regulations of the Department of Transportation.’ [49CFR172.204(a)]

Note: For shipments in company vehicles to and from job sites, the shipper’s certification is not required.

For air shipments, the following Shipper's Certification may be used:

‘I hereby certify that the contents of this consignment are fully and accurately described above by proper shipping name and are classified, packaged, marked and labeled/placarded, and are in all respects in proper condition for transport according to applicable International and national governmental regulations. I declare that all of the applicable air transport requirements have been met’

5.8

Image 63
Contents MAN-027-May Operating and Maintenance ManualTime Page Front View Exposure Device Description Applications Standard Source AssemblyModel 880 Delta authorized contents Model 880 Sigma authorized contentsSelected attenuation data Model 880 Elite authorized contentsModel 880 Omega authorized contents Source outputControl Specifications Complete Remote Control Assemblies Source Guide Tube with source stopSource Guide Tube Extension Primary Application Width Exposure Device Specifications Manufacturer LengthWeight of Exposure Device Type BU Certification Weight of Depleted Uranium ShieldConstruction Maintenance RequirementsDevice Operating Temperature Range Source AssemblyWarranty and Limitation of Liability Shielding Job site safety precautions InstrumentsRestricted Area DistanceSource Guide Tube projection sheath Layout Exposure Device SurveySimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Retracting Confirmatory SurveyLocking the Exposure Device Storage Dismantling equipment Remote control unitSource guide tubes SurveyingIntroduction Operational Features Source AssemblyExposure Device Source assembly and remote control cable connectorsDaily Inspection Instructions Exposure Mode Transit ModeDaily Inspection of the Exposure Device Daily Inspection of the SystemDaily Inspection of the Source Guide Tubes Daily Inspection of the Remote ControlsImportant Warning Remote Control InspectionControl Cable Inspection Control Conduit InspectionImportant Reminder Maintenance Instructions Radiographic Exposure Device Routine Quarterly Maintenance Requirements Remote ControlsMisconnect Test Annual Maintenance Requirements Routine Quarterly Maintenance RecordsLeak Test for Depleted Uranium DU Leak Testing Leak Test of the Radioactive Sealed SourceAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Remote Control Maintenance Requirements Annual Maintenance for the Remote ControlsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Source Guide Tube Maintenance Quarterly and Annual Maintenance for Source Guide TubesMaintenance Instructions Considerations of Safety Class a Items Annual Maintenance RecordsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Sample Transportation Instructions Transport PackageReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Automatic securing mechanism Area alarmAlarm ratemeter Apparatus for industrial gamma radiographyMaximum rating Remote controlExposure head Locked positionSource holder Source changersWorking position Training EmergenciesPersonnel Monitoring Access to Restricted AreasUnited States Regulations EU RegulationsDisposal Abc