Sigma projetor manual Model 880 Elite authorized contents, Model 880 Omega authorized contents

Page 7

TECHNICAL SPECIFICATIONS

Model 880 Elite authorized contents

Isotope

Assembly

Gamma

Half Life

Approximate

Device/Source

 

Model Number

Energy Range

 

Steel Working

Maximum

 

 

 

 

Thickness

Capacity

 

Ytterbium-169

91810

8-308 keV

32 days

2-20 mm

20 Ci

0.74 TBq

Selenium-75

A424-25W

66-401 keV

120 days

3-29 mm

150 Ci

5.55 TBq

Iridium-192

A424-9

206-612 keV

74 days

12-63 mm

50 Ci

4.81 TBq

Cobalt-60

A424-19

1.17-1.33 MeV

5.27 years

50-150 mm

25 mCi

925 MBq

Cesium-137

A424-30

663 keV

30 years

12-63 mm

380 mCi 14.0 GBq

Model 880 Omega authorized contents

Isotope

Assembly

Gamma

Half Life

Approximate

Device/Source

 

Model Number

Energy Range

 

Steel Working

Maximum

 

 

 

 

Thickness

Capacity

Ytterbium-169

91810

8-308 keV

32 days

2-20 mm

30 Ci

1.11 TBq

Selenium-75

A424-25W

66-401 keV

120 days

3-29 mm

80 Ci

2.96 TBq

Iridium-192

A424-9

206-612 keV

74 days

12-63 mm

15 Ci

0.55 TBq

Source output

Isotope

At 1 m per Ci (37 GBq)

At 1 ft per Ci (37 GBq)

Ytterbium-169

0.125 R/hr

1.25 mSv/hr

1.3 R/hr

13.0 mSv/hr

Selenium-75

0.203 R/hr

2.03 mSv/hr

2.2 R/hr

22.0 mSv/hr

Iridium-192

0.48 R/hr

4.80 mSv/hr

5.2 R/hr

52.0 mSv/hr

Cobalt-60

1.30 R/hr

13.0 mSv/hr

14.0 R/hr

140 mSv/hr

Cesium-137

0.32 R/hr

3.20 mSv/hr

3.4 R/hr

34.0 mSv/hr

Selected attenuation data

Material

Approximate

 

 

 

Approximate Half Value Thickness

 

 

 

Material

 

 

 

 

Inches (mm)

 

 

 

 

 

Density

Ytterbium-169

Selenium-75

Iridium-192

Cobalt-60

Cesium-137

 

(g/cm3)

 

 

 

 

 

 

2.400

(61.0)

 

 

Concrete

2.35

1.140

(29.0)

1.180

(30.0)

1.700

(43.2)

3.00 (76.2)

Aluminum

2.65

 

-

1.100

(27.0)

 

-

 

-

 

-

Steel

7.80

0.170

(4.3)

0.315

(8.0)

0.512

(13.0)

0.827

(21.0)

0.900

(22.9)

Lead

11.34

0.032

(0.8)

0.039

(1.0)

0.200

(5.1)

0.500

(12.7)

0.250

(6.4)

Tungsten

17.80

 

-

0.032

(0.8)

0.130

(3.3)

0.310

(7.9)

0.225

(5.7)

DU

18.70

 

-

 

-

0.050

(1.3)

0.270

(6.8)

0.125

(3.2)

Operating Distance

The distance between the remote control and the exposure head is determined by summing the length of the remote control conduits plus the total length of source guide tubes used, and normally should not exceed 47 ft (14.2 m) with standard 25 ft. controls.

Standard remote controls:

25 ft (7.6 m), 35 ft (10.7 m), 50 ft (15 m)

Standard source guide tubes (projection sheaths):

7 ft (2.1 m) set of three source guide tubes: 21 ft total (6.3 m)

1.3

Image 7
Contents MAN-027-May Operating and Maintenance ManualTime Page Front View Exposure Device Description Applications Standard Source AssemblyModel 880 Delta authorized contents Model 880 Sigma authorized contentsSelected attenuation data Model 880 Elite authorized contentsModel 880 Omega authorized contents Source outputSource Guide Tube with source stop Control Specifications Complete Remote Control AssembliesSource Guide Tube Extension Primary Application Width Exposure Device Specifications Manufacturer LengthWeight of Exposure Device Type BU Certification Weight of Depleted Uranium ShieldConstruction Maintenance RequirementsDevice Operating Temperature Range Source AssemblyWarranty and Limitation of Liability Shielding Job site safety precautions InstrumentsRestricted Area DistanceSource Guide Tube projection sheath Layout Exposure Device SurveySimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Confirmatory Survey RetractingLocking the Exposure Device Storage Dismantling equipment Remote control unitSource guide tubes SurveyingIntroduction Operational Features Source AssemblyExposure Device Source assembly and remote control cable connectorsDaily Inspection Instructions Exposure Mode Transit ModeDaily Inspection of the Exposure Device Daily Inspection of the SystemDaily Inspection of the Source Guide Tubes Daily Inspection of the Remote ControlsImportant Warning Remote Control InspectionControl Cable Inspection Control Conduit InspectionImportant Reminder Maintenance Instructions Radiographic Exposure Device Routine Quarterly Maintenance Requirements Remote ControlsMisconnect Test Annual Maintenance Requirements Routine Quarterly Maintenance RecordsLeak Test for Depleted Uranium DU Leak Testing Leak Test of the Radioactive Sealed SourceAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Remote Control Maintenance Requirements Annual Maintenance for the Remote ControlsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Source Guide Tube Maintenance Quarterly and Annual Maintenance for Source Guide TubesMaintenance Instructions Considerations of Safety Class a Items Annual Maintenance RecordsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Sample Transportation Instructions Transport PackageReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Automatic securing mechanism Area alarmAlarm ratemeter Apparatus for industrial gamma radiographyMaximum rating Remote controlExposure head Locked positionSource changers Source holderWorking position Training EmergenciesPersonnel Monitoring Access to Restricted AreasUnited States Regulations EU RegulationsDisposal Abc