MAINTENANCE INSTRUCTIONS

Annual Maintenance Records

Records of all equipment inspected and maintained during the annual maintenance must be recorded. Records should indicate:

the date of the inspection and maintenance.

name of the qualified individual performing the required inspections.

problems found and maintenance or repairs performed.

model number and serial number of the exposure device.

associated equipment that was inspected and maintained.

part numbers and associated lot numbers or serial numbers of replacement parts installed.

Model 880 Series Safety Class A Components

Safety Class A Designation Items

Items that comprise the Model 880 Series radiographic exposure device and associated equipment that are critical for safe radiological operation are classified as Class A items or components. Class A items can be structures, components and systems whose failure or function could directly result in a condition adversely affecting public health and safety. This would include extreme conditions such as the loss of primary containment with a subsequent release of radioactive material and or a loss of shielding creating a substantial safety hazard. Replacement parts that are sent to you with a safety Class A designation are clearly marked with lot numbers and contain instructions to maintain traceability.

Considerations of Safety Class A Items

Users of the Model 880 Series exposure devices and associated equipment must recognize their responsibilities of maintaining the integrity of the Type B(U)-96 (or Type A) package and the control of Safety Class A items and components by:

maintaining traceability of Class A replacement items or components to a specific exposure device or an associated component.

use of manufacturer specified items to maintain the integrity of the exposure device/transport package according to the certifications. Do not use generic grade items or components that do not meet original design specifications.

performance of periodic inspections to verify the Class A items are not excessively worn from long term use or have been damaged from accidents.

use and handling of the system consistent with its design and intended application.

promptly notifying the manufacturer in the event a Safety Class A item or component which contains a defect or deviates from the original design specifications. This action will initiate a formal evaluation of the defect or deviation.

4.17

Image 48
Contents Operating and Maintenance Manual MAN-027-MayTime Page Front View Exposure Device Description Standard Source Assembly Model 880 Delta authorized contentsModel 880 Sigma authorized contents ApplicationsModel 880 Elite authorized contents Model 880 Omega authorized contentsSource output Selected attenuation dataControl Specifications Complete Remote Control Assemblies Source Guide Tube with source stopSource Guide Tube Extension Exposure Device Specifications Manufacturer Length Weight of Exposure Device Type BU CertificationWeight of Depleted Uranium Shield Primary Application WidthMaintenance Requirements Device Operating Temperature RangeSource Assembly ConstructionWarranty and Limitation of Liability Job site safety precautions Instruments Restricted AreaDistance ShieldingExposure Device Survey Source Guide Tube projection sheath LayoutSimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Retracting Confirmatory SurveyLocking the Exposure Device Dismantling equipment Remote control unit Source guide tubesSurveying StorageOperational Features Source Assembly IntroductionSource assembly and remote control cable connectors Exposure DeviceDaily Inspection Instructions Transit Mode Exposure ModeDaily Inspection of the System Daily Inspection of the Exposure DeviceDaily Inspection of the Remote Controls Daily Inspection of the Source Guide TubesRemote Control Inspection Important WarningControl Conduit Inspection Control Cable InspectionImportant Reminder Maintenance Instructions Routine Quarterly Maintenance Requirements Remote Controls Radiographic Exposure DeviceMisconnect Test Routine Quarterly Maintenance Records Annual Maintenance RequirementsLeak Testing Leak Test of the Radioactive Sealed Source Leak Test for Depleted Uranium DUAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Annual Maintenance for the Remote Controls Remote Control Maintenance RequirementsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Quarterly and Annual Maintenance for Source Guide Tubes Source Guide Tube MaintenanceMaintenance Instructions Annual Maintenance Records Considerations of Safety Class a ItemsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Transport Package Sample Transportation InstructionsReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Area alarm Alarm ratemeterApparatus for industrial gamma radiography Automatic securing mechanismRemote control Exposure headLocked position Maximum ratingSource holder Source changersWorking position Emergencies TrainingAccess to Restricted Areas United States RegulationsEU Regulations Personnel MonitoringDisposal Abc