INSTRUCTIONS FOR DISPOSAL

Disposal

By international regulations, radioactive materials that are no longer required must be transferred to a licensed recipient for final disposition. Cobalt-60 source assemblies that have depleted beyond their useful working life may be returned to authorized recipients using a source changer authorized for the specific model source assembly.

Authorized recipients will provide any specific conditions to the shipper as required by regulatory authorities. As a minimum, sources that are transferred for a final disposition must be within a current leak test and properly secured within an authorized package before shipment.

Damaged, cropped, modified or contaminated source assemblies may require special handling and special transport containers. Notify the authorized recipient for specific instructions in these circumstances.

Depleted Uranium (DU) shielded exposure devices that are removed from service due to severe damage, worn through ‘S’ tubes or decommissioning reasons must be sent to a licensed recipient for final disposition. If the Type B transport status of a damaged exposure device is impaired, the exposure device must be transported without radioactive source assemblies. DU shielded exposure devices sent for final disposition must be properly packaged, surveyed, marked and labeled before placement into the transportation system.

Contact QSA Global, Inc. for assistance in the transfer of DU shielded exposure device for final disposition

8.1

Image 72
Contents Operating and Maintenance Manual MAN-027-MayTime Page Front View Exposure Device Description Standard Source Assembly Model 880 Delta authorized contentsModel 880 Sigma authorized contents ApplicationsModel 880 Elite authorized contents Model 880 Omega authorized contentsSource output Selected attenuation dataControl Specifications Complete Remote Control Assemblies Source Guide Tube with source stopSource Guide Tube Extension Exposure Device Specifications Manufacturer Length Weight of Exposure Device Type BU CertificationWeight of Depleted Uranium Shield Primary Application WidthMaintenance Requirements Device Operating Temperature RangeSource Assembly ConstructionWarranty and Limitation of Liability Job site safety precautions Instruments Restricted AreaDistance ShieldingExposure Device Survey Source Guide Tube projection sheath LayoutSimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Retracting Confirmatory SurveyLocking the Exposure Device Dismantling equipment Remote control unit Source guide tubesSurveying StorageOperational Features Source Assembly IntroductionSource assembly and remote control cable connectors Exposure DeviceDaily Inspection Instructions Transit Mode Exposure ModeDaily Inspection of the System Daily Inspection of the Exposure DeviceDaily Inspection of the Remote Controls Daily Inspection of the Source Guide TubesRemote Control Inspection Important WarningControl Conduit Inspection Control Cable InspectionImportant Reminder Maintenance Instructions Routine Quarterly Maintenance Requirements Remote Controls Radiographic Exposure DeviceMisconnect Test Routine Quarterly Maintenance Records Annual Maintenance RequirementsLeak Testing Leak Test of the Radioactive Sealed Source Leak Test for Depleted Uranium DUAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Annual Maintenance for the Remote Controls Remote Control Maintenance RequirementsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Quarterly and Annual Maintenance for Source Guide Tubes Source Guide Tube MaintenanceMaintenance Instructions Annual Maintenance Records Considerations of Safety Class a ItemsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Transport Package Sample Transportation InstructionsReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Area alarm Alarm ratemeterApparatus for industrial gamma radiography Automatic securing mechanismRemote control Exposure headLocked position Maximum ratingSource holder Source changersWorking position Emergencies TrainingAccess to Restricted Areas United States RegulationsEU Regulations Personnel MonitoringDisposal Abc