Sigma projetor manual Sample Transportation Instructions

Page 61

SAMPLE TRANSPORTATION INSTRUCTIONS

NOTE: For shipments in company vehicles to and from job sites, the shipper’s certification is not required.

k.The shipping papers must indicate your company's emergency telephone number. The telephone number must have 24-hour coverage in case of an emergency concerning your shipment. The telephone number must be clearly visible on the shipping paper and must be answered by a person that can provide immediate emergency response information. Beepers and pagers are not acceptable.

16For air shipments, the shipping papers must meet the requirements specified in IATA for a Shipper's Declaration for Dangerous Goods. In addition to the information listed in Step 15 of this part, the following information needs to be specified:

a.Air waybill number: Enter the number of the air waybill to which the declaration form will be attached. (This may be amended by the carrier.)

b.Aircraft limitations: Specify that the shipment is within the limitations for

‘Cargo aircraft only.’ A notation can be added in the handling information box of the Shipper's Declaration which states ‘This shipment may be carried on passenger aircraft outside U.S. jurisdiction’.

c.Airport of departure: Enter the full name of the airport of city of departure, which may be amended by the carrier.

d.Airport of destination: Enter the full name of the airport or city of destination, which may be amended by the carrier.

e.Shipment type: Specify the shipment type as ‘Radioactive’.

f.Under quantity and type of dangerous goods, specify the number of packages (of same type and content), their type of package and activity in Becquerels or multiples thereof (units used must be clearly indicated) in each package, including packages in overpacks.

(If relevant) Indication of use of overpack and dimensions of the overpack (including dimensional units). When an overpack is used, the wording ‘overpack’ must be inserted on the declaration form immediately after all the relevant entries relating to the packages within the overpack. In such cases, packages within overpacks must be listed first. Dimension units must be in multiples of meters.

g.The 24-hour emergency number required by Step 15 of this part, must appear in the ‘Additional Handling Information’ section of the Declaration for Dangerous Goods.

h.For shipment of special form radioactive material, the Special Form Certificate of Competent Authority for the radioactive source must be included. (e.g. USA/0335/S). For shipment of Type B packages also include the certificate of Competent Authority (e.g. USA/9296/BU-96)

i.The shipper’s certification must be as follows:

‘I hereby declare that the contents of this consignment are fully and accurately described above by the proper shipping name, and are classified, packaged, marked and labeled/placarded, and are in all respects in proper condition for transport according to applicable International and National governmental regulations. I declare that all of the applicable air transport requirements have been met.’

The information on the Declaration for Dangerous Goods must be entered strictly in accordance with the order specified in the latest edition of the International Air Transport Association, Dangerous Goods Regulations. Questions regarding completion of a Shipper's Declaration for Dangerous Goods should be directed to the Radiation Safety Officer.

5.6

Image 61
Contents MAN-027-May Operating and Maintenance ManualTime Page Front View Exposure Device Description Model 880 Delta authorized contents Standard Source AssemblyModel 880 Sigma authorized contents ApplicationsModel 880 Omega authorized contents Model 880 Elite authorized contentsSource output Selected attenuation dataSource Guide Tube with source stop Control Specifications Complete Remote Control AssembliesSource Guide Tube Extension Weight of Exposure Device Type BU Certification Exposure Device Specifications Manufacturer LengthWeight of Depleted Uranium Shield Primary Application WidthDevice Operating Temperature Range Maintenance RequirementsSource Assembly ConstructionWarranty and Limitation of Liability Restricted Area Job site safety precautions InstrumentsDistance ShieldingSource Guide Tube projection sheath Layout Exposure Device SurveySimultaneously pull and rotate Remote Control Conduit Layout Unlock the plunger lock with the key Important Warning Checks Before Exposure of the Source 1Unlocking Projecting Confirmatory Survey RetractingLocking the Exposure Device Source guide tubes Dismantling equipment Remote control unitSurveying StorageIntroduction Operational Features Source AssemblyExposure Device Source assembly and remote control cable connectorsDaily Inspection Instructions Exposure Mode Transit ModeDaily Inspection of the Exposure Device Daily Inspection of the SystemDaily Inspection of the Source Guide Tubes Daily Inspection of the Remote ControlsImportant Warning Remote Control InspectionControl Cable Inspection Control Conduit InspectionImportant Reminder Maintenance Instructions Radiographic Exposure Device Routine Quarterly Maintenance Requirements Remote ControlsMisconnect Test Annual Maintenance Requirements Routine Quarterly Maintenance RecordsLeak Test for Depleted Uranium DU Leak Testing Leak Test of the Radioactive Sealed SourceAnnual Maintenance for the Model 880 Series Exposure Devices Model 880 Series Annual Maintenance Requirements Maintenance Instructions Maintenance Instructions Maintenance Instructions Remote Control Maintenance Requirements Annual Maintenance for the Remote ControlsMaintenance Instructions Maintenance Instructions Re-assembly of the Remote Control Unit Source Guide Tube Maintenance Quarterly and Annual Maintenance for Source Guide TubesMaintenance Instructions Considerations of Safety Class a Items Annual Maintenance RecordsRear Plate Assembly Rear Plate Assembly Front Plate Assembly Front Plate Assembly Control Assemblies Source Guide Tubes Control Assemblies 222 Sample Transportation Instructions Transport PackageReceipt of Radioactive Material Shipment of Radioactive Material Maximum Radiation Sample Transportation Instructions Sample Transportation Instructions Shipment of Empty Uranium Shielded Containers Sample Transportation Instructions Carriage of Radioactive Material Sample Transportation Instructions Radioactive material transport checklist Alarm ratemeter Area alarmApparatus for industrial gamma radiography Automatic securing mechanismExposure head Remote controlLocked position Maximum ratingSource changers Source holderWorking position Training EmergenciesUnited States Regulations Access to Restricted AreasEU Regulations Personnel MonitoringDisposal Abc