| Table 2. | Cable Pinouts |
|
|
|
|
|
Pinout to | Pinout for | ||
|
| Female Console Port | |
|
|
|
|
Pin # | Signal | Pin # | Signal |
| Description |
| Description |
|
|
|
|
1 | Receive data (+) | 1 | DCD (output) |
|
|
|
|
2 | Receive data | 2 | TX (output) |
|
|
|
|
3 | Transmit data (+) | 3 | RX (input) |
|
|
|
|
4 | Not used | 4 | DTR (input) |
|
|
|
|
5 | Not used | 5 | SGD (ground) |
|
|
|
|
6 | Transmit data | 6 | DSR (not used) |
|
|
|
|
7 | Not used | 7 | RTS (not used) |
|
|
|
|
8 | Not used | 8 | CTS (output) |
|
|
|
|
N/A | N/A | 9 | RI (not used) |
|
|
|
|
Recommended Cable * Note: The following guidelines are based on IEEE 802.3z Draft
Distances | Document, version 3.2. |
|
| ||
|
| Table 3. Gigabit Fiber Cable Distances | |||
|
|
|
|
|
|
| Standard | Fiber | Diameter | Modal | Minimum |
|
| Type | (microns) | Bandwidth | Range |
|
|
|
| (MHz*km) | (meters) |
|
|
|
|
|
|
| MM | 62.5 | 160 | 2 to 220* | |
| MM | 62.5 | 200 | 2 to 275** | |
| MM | 50 | 400 | 2 to 500 | |
|
|
|
|
|
|
| MM | 50 | 500 | 2 to 550*** | |
| MM | 62.5 | 500 | 2 to 550# | |
| MM | 50 | 400 | 2 to 550# | |
| MM | 50 | 500 | 2 to 550 | |
|
|
|
|
|
|
|
| SM | 9 | NA | 2 to 5000 |
|
|
|
|
|
|
|
| SM | 9 | NA | 2 to 10000 |
|
|
|
|
|
|
*The TIA 568 building wiring standard calls for 160/500 MHz*km multimode fiber.
**The international ISO/IEC 11801 building wiring standard calls for 200/500 MHz*km multimode fiber.
***The ANSI Fibre Channel specification calls for 500/500 MHz*km 50 micron
multimode fiber and 500/500 fiber will be proposed for addition to ISO/IEC 11801.
# Subject to DMD distortion - be sure to use Offset Cabling.
Cajun P880 Routing Switch Installation Guide | 1 - 15 |