8.Click APPLY to save your changes, or CANCEL to restore previous settings.

Setting One-TimeTo set Summer Time Hours that are not based on a standard rule:

Summer Time Hours

1.In the System Information section of the Web Agent window, click System Clock. The System Clock dialog box opens.

2.In Clock Options, click Summer Time Hours Algorithm. The Summer Time Hours Configuration box opens.

3.From the Enable State pull-down menu, select Enable.

4.In the Offset cell of the Value column, enter the reset value for the clock in minutes.

For example, if you intend to reset the clock forward or backward by one hour, retain the default value of 60 minutes.

5.Click One-Time.

*Note: The Web Agent enables you to select the boxes next to both Recurring and One-time Summer Time Hours. However, the option to set both Recurring and One-time hours is not provided.

6.Use Table25 to configure Summer Time Hours on a one-time basis.

Table 25. One-Time Summer Time Hours Configuration

Parameter

Definition

 

 

One-time

Select if Summer Time Hours change one time, such

 

as on a specified date.

 

When you select one-time Summer Time Hours, you

 

indicate the time and date on which Summer Time

 

Hours begin and end.

 

 

Start

Specifies the start of Summer Time Hours.

 

 

End

Specifies the end of Summer Time Hours.

 

 

Cajun P880 Routing Switch Installation Guide

2 - 43

Image 77
Contents Cajun P880 Switch Installation Guide Page Table of Contents Configuring the Cajun P880 Switch Appendix a Compliance and Specification Information Cajun P880 Switch Installation Guide Documentation Feedback Overview of The ContentsConventions Online DocumentationConvention Represents Examples Indicates a condition that may damage hardware orRelated Documents AudienceLucent Documents Reference DocumentsContacting Lucent Corporation Verifying the System Components OverviewAll power cords Before servicing to avoid electric shock This unit has more than one power-supply cord. DisconnectFrench GermanAir Flow Requirements Selecting a LocationPreventing Electrostatic Discharge Installing the SystemRequired Tools and Hardware Installing the Mounting Shelf Installing the Mounting ShelfRack Mounting the System Installing the ChassisSecuring the chassis to the Rack Finger Pulls Attaching the Trim PiecesDevice Power Added/Used Installing/Removing Power SuppliesInstalling the Power Supply Support the bottom of the power supply with your free hand Installing/Removing Power SuppliesRemoving a Power Supply Filler Panel Removing a Power SupplyRemoving Power Supply Filler Panel Connecting the Power SuppliesInstalling Modules Installing the ModulesClosing the Ejector Tabs Installing the Cables1000BASE-LX 1000BASE-SLX DistancesCable Description Maximum Cable Length Fiber Cable Description Maximum Cable LengthHalf-duplex connection 412 m Full-duplex connection Category 5 twisted pair cable 100 mInstalling the Cable Management Bracket Installing the Cable Management BracketInstalling/Removing Fan Assemblies Replacing Fan Assemblies Installing Chassis Fan AssembliesInstalling Rear Fan Assemblies Installing Redundant Controllers/Elements Installing/Removing Switch Controllers/ElementsInstalling Switch Elements/Switch Controllers Power-On Sequence Powering On the SystemModule Normal BehaviorPost Power-on Configuration Series Mode Configuring the Cajun P880 SwitchSeries Mode Configuring the Supervisor Module Using the CLI Terminal SettingsBaud Stop Bits Data Bits Flow Parity Rate Control 600 Xon/Xoff NoneCajun P880 Routing Switch Installation Guide Password Layer 2 Setup Command Display Cajun P880 Switch Configuring the Switch Using the Web AgentLogging Into the Web Agent Setting Up User AccountsClick Login. The Username/Password dialog box opens Administrator AD Configuring Port Parameters Using the Web AgentUser Level Can Cannot UserConfiguring Physical Port Parameters on Gigabit Ports Parameter Definition Fault Detect Configuring Physical Port Parameters on Fast Ethernet PortsPort Pace PriorityCajun P880 Routing Switch Installation Guide Negotiation is enabled, this setting is Speed ModeDuplex Mode Full-duplex. If auto-negotiation is enabledAuto Flow ControlNegotiation Speed/DuplexBurst Size Using the All Ports Configuration Dialog BoxViewing Switch Port Parameters Configuring Switch Port Parameters Frame Tags Trunk ModeParameter Definition Port Vlan Parameter Definition Vlan Binding Known ModeAutomatic Vlan CreationClear Configuring Port Vlan ParametersIEEE-802.1Q Multi-layerStatic Option DefinitionBind to AllConfiguring VTP Snooping Configuring Non-VLAN Switch Port Parameters Parameter Recommended Setting Configuring Fast Start Mode Using the All Ports Configuration Dialog Box Community String field, enter a community name Setting Up Snmp CommunitiesOption Allows Access to Access Level Manager Can CannotOption Default Available Settings Changing the Console Serial Port SettingsConfiguring Serial Console Port As a TTY Console Typical Connection Between the Switch and a Modem Disable DTR Configuring Dial-Up Networking Use flow control, click Software XON/XOFF Cajun P880 Routing Switch Installation Guide Mask field, enter the network mask IP address Configuring a Static Route for the PPP ConsoleHardware Requirements for Routing Configuring IP Routing on the Switch Entering General System Information Configuring System InformationEnabling Sntp Setting Summer Time HoursClick Recurring Summer Time HoursStart RecurringEnd WeekDay Select RecurringMonth HourOne-time Click One-TimeSelect the week of the month during which you Setting the System Clock Displaying the Power System Statistics Setting the Temperature SystemDisplaying Cooling System Statistics Configuring Redundant HardwareChecking for Proper Installation Replacing the Primary Controller Properly-Installed Redundant Hardware SettingsReplacing an Element Performing a System Reset Managing Configuration FilesViewing Your Script Execution Log File Viewing Your Running ConfigurationViewing Your Startup Configuration Copying Files Copying Configuration FilesCopying Running Configuration to Startup Configuration Parameter Description Options Destination Copy DestinationFilename Tftp Server IPCajun P880 Routing Switch Installation Guide Get Status of Most Recent Tftp Copy field, click Status Viewing the Status of a Tftp TransferCajun P880 Routing Switch Installation Guide Power SafetyOperating/Physical Numerics IndexCLI Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide Cajun P880 Switch Installation Guide