Table 26. Power System Statistical Parameters
Parameter | Definition |
|
|
Total System | Displays the total system power in Watts. |
Power |
|
|
|
Current | Displays the current power available. |
Power |
|
Available |
|
|
|
*Note: The power system settings only display 1400W of available power with two or three power supplies installed. A maximum configured switch requires a maximum of two power supplies. A third power supply may be added for redundancy in the event one of the other power supplies fails. All three power supplies will
Displaying Cooling System Statistics
To display the switch’s cooling system status:
1.In the System Information section of the Web Agent window, click Cooling System. The Cooling System dialog box opens.
2.Ensure that all the individual components are operational by checking the status column for each component.
3.If a component’s status is
Configuring Redundant Hardware
The Cajun P880 switch provides a redundant controllers and elements to ensure that if a controller or an element fails, the switch will continue to route data properly. The redundant components are available as separate options.
Cajun P880 Routing Switch Installation Guide | 2 - 47 |