AMD manual 1207 PIB, Keep-Out, 318 000 885

Page 42

42

Keep-Out Drawings for Platforms Using the PIB Thermal Solution for Socket F (1207) Processors

Appendix A

Figure 16.

 

Socket

D

F (1207) PIB

 

Board

C

No-Through-Hole

B

Keep-Out

 

 

A

8

7

6

5

4

3

2

1

N o - T h r o u g h - H o l e C o m p o n e n t s Z o n e

D

4

9

. 3

7

1

. 9 4

4

 

 

 

 

 

 

C

P i n A 1

 

 

 

 

 

 

0

. 0 0

 

0 . 0 0 0

 

1

2

. 6

3

0

. 4 9

7

1.318

 

0.000

2.885

B

 

 

 

 

 

 

33.47

 

0.00

73.29

 

 

 

 

 

 

 

 

A D V A N C E D M I C R O D E V I C E S

 

 

 

 

 

 

T I T L E :

A U S T I N , T E X A S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S o c k e t F ( 1 2 0 7 ) P r o c e s s o r C o m p o n e n t

A

 

 

 

 

 

 

K e e p o u t a n d H e i g h t R e s t r i c t i o n s C o m p l i a n t

 

 

 

 

 

 

 

w i t h A M

D P I B

 

N o t h r o u g h h o l e c o m p o n e n t s

 

 

 

 

 

D W G .

N O .

R E V

 

 

 

 

 

7 9 Z 0 0 0 0 1 2 4

2 . 1

 

 

 

 

 

 

 

 

 

 

 

 

 

S H E E T 5

O F 6

8

7

6

5

4

3

2

1

 

Thermal Design Guide for Socket F (1207) Processors

32800 Rev. 3.02 August 2006

Image 42
Contents Thermal Design Guide for Socket F 1207 Processors Advanced Micro Devices, Inc. All rights reserved Contents Heat Sink Fans Thermal Interface Material List of Figures List of FiguresList of Figures List of Tables List of TablesList of Tables Revision History Revision HistoryRevision History Summary of Requirements Chapter IntroductionChapter Processor Specifications Chapter Processor Thermal SolutionsSocket Description 1207-Pin SocketMotherboard Component Height Restrictions Thermal Solution Design Requirements Sample Heat Sinks and Attachment MethodsPart Description Material Quantity Backplate Assembly Retention Frame Thermal Design of Platforms Using the AMD Processor-In-a Thermal Design of Custom 1U-2P Systems Chapter Thermal Design of Custom 1U-2P SystemsSymbol Systems Exploded View of Thermal Solution for Custom 1U-2P Systems Spring ScrewsHeat Sink Fin ParametersFans Thermal Interface Material Thermal Design of Custom 1U-2P Systems Thermal Design of Custom 2U-4P Systems Chapter Thermal Design of Custom 2U-4P SystemsThermal Solution Design Requirements Heat sink Aluminum Fan Plastic Spring clip Backplate Assembly Spring Clip Chemical Element of SK7 Spring SteelHigh Performance Heat Sink for Custom 2U-4P Systems Fans Thermal Design of Custom 2U-4P Systems Solution for Socket F 1207 Processors Appendix aSocket F 1207 PIB Board Component Height Restrictions 787 64.36 76.41 49.91 59.81Socket F 1207 PIB Socket Outline and Socket Window 724 000 784 520 1892x11.44 2x51.26 2x61.08 1207 PIB Heat Sink HeightZone 36.59 32.13 27.591207 PIB Keep-Out318 000 885 Thermal 23310.09 33.91 49.91 Solution for Socket F 1207 Processors Appendix B Socket F 1207 Processor2P Systems Processor Drawings for1207 Height RestrictionsNo-Routing Zone BasedHoles, Contact Pads, 32.16 71.98 24.54 10.09 49.91 64.36Processor Based onWindow 1U-2P Systems 1207 Processor Height Restriction Zone42.71 82.53 32.16 71.98 Out Keep-Out2P Board No-Through-Hole Keep 598 000 166 40.59 80.4135.04 1207 1U233 335 965 22.04 10.09 33.9 49.91 61.86Socket F 1207 Processor Appendix C Socket F 1207 2U-4P Board Component Height Restrictions 24.54 64.36 4P Mounting Holes, Contact Pads, and No-Routing Zone47.40 87.22 35.65 75.47Custom 2U-4P 1207 2U-4P Socket OutlineSocket Window 260 2U-4P Systems 1207 Processor17.59 681 266Socket F 1207 2U-4P Board No-Through-Hole Keep-Out 40.59 80.411207 166 80.41Socket F 1207 Processor Appendix D Socket F 1207 ProcessorsStreamline Plot of AMD Reference Custom 2U-4P System