Orion Car Audio 1892 1335 manual Messages from Base Station to Outstation, IDS IDD 20 CH

Page 31

Messages from Base Station to Outstation:

04

IDS IDD 20 CH

Poll outstation IDD

 

 

Note: IDS = 0 for base station

 

 

 

04

IDS IDD 21 nn tt dd ss CH

Set input trigger state for digital input port nn

 

 

Logic 1 in byte tt = send alarm message, 0 = don’t

 

 

Dwell time dd, (1 -255)*10ms, (0 = no dwell time)

 

 

Logic 0 in byte ss indicates a High to Low change

 

 

Logic 1 in byte ss indicates a Low to High change

 

 

 

04

IDS IDD 22 nn cc llll dd ss

Set analogue input set by bit in byte nn to:

CH

 

Analogue input type: cc = 1, 20mA; cc = 2, 0 - 5V; cc = 3; 0 -

 

 

 

 

10V

 

 

ADC trip level ll, 1 - 1024, (0 = no trip level)

 

 

Note: if trip level = 0, no alarm message sent

 

 

Dwell time dd, (1 -255)*10ms, (0 = no dwell time)

 

 

If bit 0 in byte ss = 1 then alarm sent if above trip level

 

 

If bit 0 in byte ss = 0 then alarm sent if below trip level

 

 

 

04

IDS IDD 23 nn mmmm CH

Set analogue output port nn to ADC value mmmm

 

 

 

04

IDS IDD 24 nn CH

Set digital outputs:

 

 

Logic 0 in byte nn indicates output = Low

 

 

Logic 1 in byte nn indicates output = High

 

 

 

04

IDS IDD 25 pp dd CH

Enable/Disable pulse count input:

 

 

If pp = 1, enable pulse count (Input bit 1) with Dwell time dd, (1 -

 

 

255)*10ms, (0 = no dwell time)

 

 

If bit 0 of pp = 0, disable pulse count (Input bit 1)

 

 

 

04

IDS IDD 26 bbbb CH

Set battery trip level to ADC value bbbb (1 to 1023, where 1023

 

 

= 50VDC)

 

 

 

04

IDS IDD 27 CH

Store config in EEPROM

 

 

 

04

IDS IDD 28 aa ff CH

Set channel of outstation to value ff (0 to 99) where aa is + or -

 

 

from centre frequency.

 

 

Channel change will occur after acknowledge message

 

 

received.

 

 

 

04

IDS IDD 29 bb CH

Set TX power to level bb

 

 

If bb = 0 then LOW, if bb = 1 then HIGH

 

 

 

04

IDS IDD 30 bbbb CH

Set Pulse Counter alarm trip level (1 to 1023)

 

 

 

04

IDS IDD 31 nn CH

Read setup for digital input port nn

 

 

 

04

IDS IDD 32 nn CH

Read setup for analogue input port nn

 

 

 

04

IDS IDD 33 CH

Read Pulse Counter alarm level

 

 

 

04

IDS IDD 40 CH

Read analogue input ADC level for all ports

 

 

 

04

IDS IDD 41 CH

Read state of digital inputs

 

 

 

04

IDS IDD 42 nn CH

Read analogue input ADC value for port nn

 

 

 

1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006

31

Image 31
Contents Orion Radio Modem Orion Radio Modem with I/O Operating InstructionsOverview Shows the Orion in block diagram formPage Options When Ordering Physical InstallationDimensions of Orion PCB mm RJ45 Port Pin No Digital Digital Out Analogue Analogue Out ConnectionsTXB Pin No RS232 RS422 RS485Graphical User Interface GUI Hardware Link Settings Setting UP AN OrionOption Choice Links Using the GUIPage COM Ports and General Status Modem Modes TMR TNT TMX TNX TOM TOS TRR TSR TURTOR TOT TOX TOT Modem Parameter ConfigurationPage This space reserved for additional material Analogue In Set-up Telemetry Option ConfigurationAlarms This space reserved for additional material LED Indications OperationWait+++waitenter Appendix a AT Command CodesATS154= Command SyntaxEnd Command Mode Letter 0, not zero Ending Command Mode ATOCommands Description Values Start Command Mode Wait period set by ATS154=AT&Y8 AT&F=AT&F? AT&WATPT= ATPF?ATPRT= ATPRT?ATS168= ATS166?ATS167= ATS167?ATT? Introduction Appendix B OVER-AIR Command CodesIDS IDD 20 CH Messages from Base Station to OutstationIDS IDD 45 CH IDS IDD 51 nn tt dd ss CH Messages from Outstation to Base StationIDS IDD 65 nn cccc CH Page Appendix C ATT? Parameter String Structure