Orion Car Audio 1892 1335 manual IDS IDD 65 nn cccc CH

Page 34

04

IDS IDD 60 aaaa bbbb cccc dddd

Analogue input levels (reply to 40 command)

CH

 

aaaa = ADC level of analogue input 0, 1 - 1023

 

 

 

 

bbbb = ADC level of analogue input 1, 1 - 1023

 

 

cccc = ADC level of analogue input 2, 1 - 1023

 

 

dddd = ADC level of analogue input 3, 1 - 1023

 

 

 

04

IDS IDD 61 nn CH

Digital input levels (reply to 41 command or after an

 

 

alarm)

 

 

Logic 0 in byte nn indicates output = Low

 

 

Logic 1 in byte nn indicates output = High

 

 

 

04

IDS IDD 62 nn aaaa CH

Analogue input level for port nn (reply to 42 command or

 

 

after an alarm)

 

 

aaaa = ADC level of analogue input nn 1 - 1023

 

 

 

04

IDS IDD 65 nn cccc CH

Pulse counter value (reply to 45 command)

 

 

cccc = 1 - 1023

 

 

 

04

IDS IDD 66 cccc pp CHCH

Used channel and power setting (reply to 46 command)

 

 

cccc = channel 1 - 400

 

 

pp = 0, low power and pp = 1, high power

 

 

 

04

IDS IDD 67 nn aaaa CH

Analogue output level for port nn (reply to 47 command)

 

 

aaaa = 1 - 255 with 16 bit reserved

 

 

 

04

IDS IDD 68 nn CH

Digital output status (reply to command 47)

 

 

Logic 0 in byte nn indicates output = Low

 

 

Logic 1 in byte nn indicates output = High

 

 

 

04

IDS IDD 69 bbbb CH

Power supply battery trip level (reply to command 49)

 

 

bbbb = alarm trip level 1 - 1023

 

 

 

04

IDS IDD 70 bbbb CH

Pulse counter alarm trip level (reply to commands 30 and

 

 

33)

 

 

bbbb = 1 - 1023

 

 

 

04

IDS IDD 73 bbbb CH

Poll counter alarm trip level (reply to command 30)

 

 

bbbb = 1 - 1023

 

 

 

04

IDS IDD 74 aaaa CH

RSSI level for last received message (reply to command

 

 

48)

 

 

aaaa = 1 - 1023

 

 

 

04

IDS IDD 91 nn bb CH

Digital input alarm for port nn

 

 

00 in byte bb indicates output = Low

 

 

FF in byte bb indicates output = High

 

 

 

04

IDS IDD 92 aaaa CH

Analogue input alarm for port nn

 

 

aaaa = 1 - 1023

 

 

 

04

IDS IDD 93 aaaa CH

Pulse count alarm when pulse count > alarm trip level

 

 

aaaa = 1 - 1023

 

 

 

34

1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006

Image 34
Contents Orion Radio Modem with I/O Operating Instructions Orion Radio ModemShows the Orion in block diagram form OverviewPage Options When Ordering Installation PhysicalDimensions of Orion PCB mm Connections RJ45 Port Pin No Digital Digital Out Analogue Analogue OutPin No RS232 RS422 RS485 TXBGraphical User Interface GUI Setting UP AN Orion Hardware Link SettingsUsing the GUI Option Choice LinksPage COM Ports and General Status Modem Modes TRR TSR TUR TMR TNT TMX TNX TOM TOSModem Parameter Configuration TOR TOT TOX TOTPage This space reserved for additional material Telemetry Option Configuration Analogue In Set-upAlarms This space reserved for additional material Operation LED IndicationsAppendix a AT Command Codes Wait+++waitenterCommand Syntax ATS154=Start Command Mode Wait period set by ATS154= Ending Command Mode ATOCommands Description Values End Command Mode Letter 0, not zeroAT&W AT&F=AT&F? AT&Y8ATPRT? ATPF?ATPRT= ATPT=ATS167? ATS166?ATS167= ATS168=ATT? Appendix B OVER-AIR Command Codes IntroductionMessages from Base Station to Outstation IDS IDD 20 CHIDS IDD 45 CH Messages from Outstation to Base Station IDS IDD 51 nn tt dd ss CHIDS IDD 65 nn cccc CH Page Appendix C ATT? Parameter String Structure