Orion Car Audio 1892 1335 manual Pin No RS232 RS422 RS485, Txb

Page 8

Serial Port

9-way D-type male connector - NOT a standard serial port

vProtocol (RS232, RS422 or RS485) is fixed by soldered links. See page 10.

Pin No

 

RS232

 

RS422

 

RS485

 

 

 

 

 

 

1

SHDN

Modem on/off input

 

 

 

 

If < 0.6V, Modem = OFF

 

 

 

 

If o/c (internal pull-up to +5V) Modem = ON

 

 

 

 

 

 

 

 

2

RXD

Receive Data

OP

Receive Data

IO

Inverting

 

 

output

 

inverting output

 

input/output

 

 

 

 

 

 

 

3

TXD

Transmit Data

IP

Transmit Data input

NC

No function

 

 

input

 

 

 

 

 

 

 

 

 

 

 

4

TXB

Secondary

NC

No function

NC

No function

 

 

Transmit Data

 

 

 

 

 

 

input

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

0V

 

 

 

 

 

6

 

VSENSE External Battery Monitor input +50VDC max

 

 

 

 

 

 

 

7

RTS

RTS input

IP

Transmit Data

NC

No function

 

 

 

 

inverting input

 

 

 

 

 

 

 

 

 

8

CTS

CTS output

OP

Receive Data

IO

Non-inverting

 

 

 

 

output

 

input/output

 

 

 

 

 

 

 

9

RXB

Secondary

NC

No function

NC

No function

 

 

Receive Data

 

 

 

 

 

 

output

 

 

 

 

 

 

 

 

 

 

 

8

1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006

Image 8
Contents Orion Radio Modem with I/O Operating Instructions Orion Radio ModemShows the Orion in block diagram form OverviewPage Options When Ordering Installation PhysicalDimensions of Orion PCB mm Connections RJ45 Port Pin No Digital Digital Out Analogue Analogue OutPin No RS232 RS422 RS485 TXBGraphical User Interface GUI Setting UP AN Orion Hardware Link SettingsUsing the GUI Option Choice LinksPage COM Ports and General Status Modem Modes TRR TSR TUR TMR TNT TMX TNX TOM TOSModem Parameter Configuration TOR TOT TOX TOTPage This space reserved for additional material Telemetry Option Configuration Analogue In Set-upAlarms This space reserved for additional material Operation LED IndicationsAppendix a AT Command Codes Wait+++waitenterCommand Syntax ATS154=Ending Command Mode ATO Commands Description ValuesStart Command Mode Wait period set by ATS154= End Command Mode Letter 0, not zeroAT&F= AT&F?AT&W AT&Y8ATPF? ATPRT=ATPRT? ATPT=ATS166? ATS167=ATS167? ATS168=ATT? Appendix B OVER-AIR Command Codes IntroductionMessages from Base Station to Outstation IDS IDD 20 CHIDS IDD 45 CH Messages from Outstation to Base Station IDS IDD 51 nn tt dd ss CHIDS IDD 65 nn cccc CH Page Appendix C ATT? Parameter String Structure