Orion Car Audio 1892 1335 ATS166?, ATS167=, ATS167?, ATS168=, ATS168?, ATS169=, ATS169?, ATS170=

Page 28

ATS166?

Get Sync tolerance

 

2

4 mismatches

 

3

6 mismatches

 

 

 

ATS167=

Set Inverted Symbol

 

0

None invert

 

1

TX invert

 

 

 

ATS167?

Get Inverted Symbol

 

2

RX invert

state

 

3

Both invert

 

 

ATS168=

Set Squelch delay

 

1 to 255

ms

ATS168?

Get Squelch delay

 

 

ATS169=

Set Destination ID

001 to 249

Master/slave modes only

ATS169?

Read destination ID

 

 

ATS170=

Set Unit ID

001 to 249

Master/slave modes only

ATS170?

Read Unit ID

 

 

ATS172=

Set Low battery

 

 

threshold

 

 

 

0 - 1023

Proportion of full charge

ATS172?

Get Low battery

 

 

threshold

 

 

 

 

 

ATS175n=m

Set Analogue input n

 

m = 1

0 to 20mA

type

 

m = 2

0 to 5V

 

 

ATS175n?

Read Analogue input

 

 

 

 

n h/w configuration

 

m = 3 (default)

0 to 10V

 

 

ATS176n=a

Set Analogue output n

 

 

 

to DAC value a

0 to 1023

 

 

ADC level

ATS176n?

Read Analogue input n

(Default = 0)

 

level

 

 

 

 

 

 

Set parameters of

 

l = 0 to1023

trip level 1 – 1023

 

 

 

ATS177n=l,d,s

analogue input 'n'

 

 

0 = no alarm

 

(Defaults = 0, 0, 0)

 

d = 1 - 255

d = dwell time*10ms

 

 

 

 

 

 

 

 

 

Read Analogue input

 

 

transition causing alarm:

ATS177n?

 

s = 0 or 1

s = 0, high to low

n setup

 

 

 

 

 

 

 

s = 1, low to high

ATS178n=m

Set Digital O/P n high

 

m = 0

Output = Low

or low (Default = 1)

m = 1

Output = High

 

ATS178?

Read Digital I/Ps 0 - 3

value = 0

Input = Low

value = 1

Input = High

 

 

 

 

Set parameters of

 

t = 0 or 1

t = 0, no alarm

 

 

 

ATS179n=t,d,s

digital input 'n'

 

 

t = 1, alarm

 

(Defaults = 0, 0, 0)

 

d = 1 - 255

d = dwell time*10ms

 

 

 

ATS179n?

Read digital input

 

 

 

 

s = 0 or 1

s = 0, high to low

 

 

 

status

 

s = 1, low to high

 

 

 

 

ATS180=

Set RX-TX priority

0 or 1

0 =TX waits for squelch

 

 

 

 

ATS180?

Read RX-TX priority

1 =TX at any time

 

ATS181=

Set Pulse Count input

0 or 1

1 = on

on/off (input 0 only)

0 = off

 

 

ATS181?

Read Pulse Count &

0 to 65535

counts since last reset

reset to 0

 

 

 

28

1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006

Image 28
Contents Orion Radio Modem with I/O Operating Instructions Orion Radio ModemShows the Orion in block diagram form OverviewPage Options When Ordering Installation PhysicalDimensions of Orion PCB mm Connections RJ45 Port Pin No Digital Digital Out Analogue Analogue OutPin No RS232 RS422 RS485 TXBGraphical User Interface GUI Setting UP AN Orion Hardware Link SettingsUsing the GUI Option Choice LinksPage COM Ports and General Status Modem Modes TRR TSR TUR TMR TNT TMX TNX TOM TOSModem Parameter Configuration TOR TOT TOX TOTPage This space reserved for additional material Telemetry Option Configuration Analogue In Set-upAlarms This space reserved for additional material Operation LED IndicationsAppendix a AT Command Codes Wait+++waitenterCommand Syntax ATS154=Ending Command Mode ATO Commands Description ValuesStart Command Mode Wait period set by ATS154= End Command Mode Letter 0, not zeroAT&F= AT&F?AT&W AT&Y8ATPF? ATPRT=ATPRT? ATPT=ATS166? ATS167=ATS167? ATS168=ATT? Appendix B OVER-AIR Command Codes IntroductionMessages from Base Station to Outstation IDS IDD 20 CHIDS IDD 45 CH Messages from Outstation to Base Station IDS IDD 51 nn tt dd ss CHIDS IDD 65 nn cccc CH Page Appendix C ATT? Parameter String Structure