COM Ports and General Status
Figure 12 - COM Port tab
This tab is the first one which the GUI presents to you, because the GUI must be set to the same baud rate and parity as the port on the Orion in order to communicate with it.
If the message Modem connected does not appear immediately, select the correct baud rate and parity, then click the COMn radio button (even if it is already selected), where n is the number of the port to which the Orion is connected. The message Modem connected appears.
To change the baud rate or parity, select the values you want, then select Link, Write Parameters from the menu bar. A successful outcome is reported in the yellow message area.
vThe baud rate and/or parity do not actually change at the GUI until you click the one of the COM radio buttons.
vThe baud rate and/or parity do not actually change at the Orion until you disconnect from it.
To disconnect from the Orion, click the DISC button.
Modem Status
You can also read the unit serial number, firmware release and general status on this tab.
If one or more errors exist, this will be displayed together with a single code number which you can give to Wood & Douglas technical support.
Some possible errors are listed below.
vNO VALID PARAMETERS IN MODEM! (Error code 2)
When the factory set-up was uploaded to the modem FLASH and EEPROM memories, a parameter check sum was also written. If the check sum calculated by the modem does not match the written check sum, this error will be generated, indicating that the FLASH and EEPROM memory contents are corrupt. You can use menu item Troubleshooting, Reprogram with Factory Settings to correct the parameters, or upload your own custom settings to the modem in the normal way.