Seagate ST3600002FC, ST3300602FC, ST3450802FC manual Reference documents, Ncits TR-19

Page 11

2.3Reference documents

SCSI Commands Reference Manual

Fibre Channel Interface Manual

ANSI Fibre Channel Documents X3.230-1994

X3.297.1997

X3.303.1998

X3.272-1996

X3.269-1996

NCITS TR-19

NCITS TR-20 SFF-8045 SFF-8067

Seagate part number: 100293068

Seagate part number: 100293070

FC Physical and Signaling Interface (FC-PH)

FC-PH-2 Fibre Channel Physical and Signaling Interface-2 FC-PH-3 Fibre Channel Physical and Signaling Interface-3 FC Arbitrated Loop (FC-AL)

Fibre Channel Protocol for SCSI (FCP) Private Loop SCSI Direct Attach (PLDA) Fabric Loop Attachment (FC-FLA)

Specification for 40-pin SCA-2 Connector with Parallel Selection Specification for 40-pin SCA-2 Connector with Bidirectional Enclosure Services Interface

ANSI Small Computer System Interface (SCSI) Documents

X3.131-1994

(SCSI-2)

 

X3.270-1996

(SCSI-3) Architecture Model

NCITS 305-199X

(SCSI-3) Enclosure Services

Specification for Acoustic Test Requirement and Procedures

 

 

Seagate part number: 30553-001

Package Test Specification

Seagate P/N 30190-001

(under 100 lb.)

Package Test Specification

Seagate P/N 30191-001

(over 100 lb.)

In case of conflict between this document and any referenced document, this document takes precedence.

Cheetah NS 10K.2 FC Product Manual, Rev. B

5

Image 11
Contents ST3600002FC ST3450802FC ST3300602FC Cheetah NS 10K.2 FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityCompliance Ncits TR-19 Reference documentsCheetah NS 10K.2 FC Product Manual, Rev. B General description Media description Standard featuresFormatted capacities PerformanceReliability Programmable drive capacity Factory-installed optionsUser-installed accessories Seek performance Performance characteristicsInternal drive characteristics Access timeST3600002FC ST3450802FC ST3300602FC Format command execution time minutesGeneral performance characteristics Start/stop timeCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsPerformance impact A.R.T. delay times4 S.M.A.R.T Controlling S.M.A.R.TThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingTemperature Log Page 0Dh Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bAbort Product warrantyCheetah NS 10K.2 FC Product Manual, Rev. B DC power requirements for ST3600002FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST3450802FC model Gbit Amps DC power requirements for ST3300602FC model Gbit Amps General DC power requirement notesCurrent profiles Power sequencingConducted noise immunity Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B ST3600002FC Power dissipationST3450802FC ST3300602FC Relative humidity Temperature a. OperatingEnvironmental limits Shock Effective altitude sea level a. OperatingShock and vibration Recommended mounting Package size Packaged/product weight Drop heightCorrosive environment Air cleanlinessVibration a. Operating-normal AcousticsChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsCheetah NS 10K.2 FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.81 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS 10K.2 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Supported Feature or condition Miscellaneous operating features and conditionsPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Technical Support Seagate Technology support servicesPresales Support Data Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC