Seagate ST3450802FC, ST3300602FC, ST3600002FC manual Flogi

Page 85

corruption 57

Firmware download option command 56 Firmware numbers page command 54 flawed sector reallocation 8

FLOGI

received on Port A 51 received on Port B 51

Force unit access command 55 form factor 8

format 43

Format command execution time 12 Format page (03h) command 54 Format unit command 54

FS 49, 50, 52 function

complete, code 00 48

not supported, code 05 48 reject, code 04 48

G

Good status 63 gradient 32 ground shift noise 66 grounding 45

H

hard assigned arbitrated loop physical address (AL_PA) 43

HDA 45 heads

read/write data 11 heat removal 43 host equipment 45

hot plugging the drive 16 humidity 32

humidity limits 32

I

IC 49

ID and configuration options 8 Idle Read After Write 42

Implemented operating def. page command 54 Information exceptions control page (1Ch) command

55 Initiator control 49 Inquiry command 54 inquiry data 58 installation 43

guide 5 interface 43

commands supported 54 description 64

error rate 15 errors 16

illustrated 64 physical 64 requirements 47

intermediate/condition met/good status 63 intermediate/good status 63

Intermix 49, 52 internal data rate 11 internal defects/errors 39 internal drive characteristics 11 IRAW 42

J

J1 connector 43

Jumper settings page command 54 jumpers 43

L

latency

average rotational 11 LBdata 56

LED driver signals 72

Link Service Reject (LS_RJT) 47 link services supported 47 Lock-unlock-cache command 56 Log select command 56

Log sense command 56 logic power 67

logical block address 13

logical block reallocation scheme 8 logical block size 8, 12

logical segments 13 Logout (LOGO) 47 loop 64, 68

disruption 16 initialization 43

loop position

FC-AL options 53 loop position report

FC-AL options 53 LS_RJT 49, 52

M

maintenance 15

maximum delayed motor start 23, 24, 25 maximum start current 23, 24, 25 mean time between failure (MTBF) 16 media description 8

Media Pre-Scan 41 miscellaneous feature support

Adaptive caching 63 Asynchronous event notification 63 Automatic contingent allegiance 63 Deferred error handling 63 FC-AL selective reset 63

Cheetah NS 10K.2 FC Product Manual, Rev. B

79

Image 85
Contents ST3600002FC ST3450802FC ST3300602FC Cheetah NS 10K.2 FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS 10K.2 FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities User-installed accessories Factory-installed optionsProgrammable drive capacity Internal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time ST3600002FC ST3450802FC ST3300602FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenance4 S.M.A.R.T A.R.T. delay timesControlling S.M.A.R.T Performance impactDetermining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyCheetah NS 10K.2 FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps DC power requirements for ST3300602FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B ST3600002FC Power dissipationST3450802FC ST3300602FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Recommended mounting Package size Packaged/product weight Drop heightVibration a. Operating-normal Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsCheetah NS 10K.2 FC Product Manual, Rev. B Drive internal defects/errors Defect and error managementDrive error recovery procedures 77.81 Background Media Scan FC-AL system errorsMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Inquiry data Mode Sense dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Supported Feature or condition Miscellaneous operating features and conditionsFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Presales Support Seagate Technology support servicesTechnical Support Data Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC