Seagate ST3450802FC manual Package size Packaged/product weight Drop height, Recommended mounting

Page 40

d.Packaged

Disk drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from heights as defined in the table below. For additional details refer to Seagate specifications 30190-001 (under 100 lbs/45 kg) or 30191-001 (over 100 lbs/45 Kg).

Package size

Packaged/product weight

Drop height

<600 cu in (<9,800 cu cm)

Any

60 in (1524 mm)

600-1800 cu in (9,800-19,700 cu cm)

0-20 lb (0 to 9.1 kg)

48 in (1219 mm)

>1800 cu in (>19,700 cu cm)

0-20 lb (0 to 9.1 kg)

42 in (1067 mm)

>600 cu in (>9,800 cu cm)

20-40 lb (9.1 to 18.1 kg)

36 in (914 mm)

Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for general freight shipment shall withstand a drop test from 48 inches (1,070 mm) against a concrete floor or equivalent.

Z

X

Y

Z

Y

X

Figure 8. Recommended mounting

34

Cheetah NS 10K.2 FC Product Manual, Rev. B

Image 40
Contents Cheetah NS 10K.2 FC ST3600002FC ST3450802FC ST3300602FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Standards, compliance and reference documents StandardsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Reference documents Ncits TR-19Cheetah NS 10K.2 FC Product Manual, Rev. B General description Standard features Media descriptionReliability PerformanceFormatted capacities User-installed accessories Factory-installed optionsProgrammable drive capacity Performance characteristics Internal drive characteristicsAccess time Seek performanceFormat command execution time minutes General performance characteristicsStart/stop time ST3600002FC ST3450802FC ST3300602FCPrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenanceA.R.T. delay times 4 S.M.A.R.TControlling S.M.A.R.T Performance impactReporting control Determining ratePredictive failures Thermal monitorState of the drive prior to testing Temperature Log Page 0DhDrive Self Test DST DST failure definitionInvoking DST Short and extended testsShort test Function Code 001b Extended test Function Code 010bProduct warranty AbortCheetah NS 10K.2 FC Product Manual, Rev. B Physical/electrical specifications AC power requirementsDC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps General DC power requirement notes DC power requirements for ST3300602FC model Gbit AmpsConducted noise immunity Power sequencingCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B Power dissipation ST3600002FCST3450802FC ST3300602FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Package size Packaged/product weight Drop height Recommended mountingAir cleanliness Vibration a. Operating-normalAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mechanical specifications Mounting configuration dimensionsCheetah NS 10K.2 FC Product Manual, Rev. B Drive internal defects/errors Defect and error managementDrive error recovery procedures 77.81 Background Media Scan FC-AL system errorsMedia Pre-Scan Deferred Auto-Reallocation Idle Read After WriteInstallation Drive ID/option selectionDrive orientation CoolingDrive mounting Air flowGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B FC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept Fibre Channel Process LoginNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Inquiry data Mode Sense dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Miscellaneous operating features and conditions Supported Feature or conditionFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-SCA pin descriptions Pin Signal name Signal type FC-AL transmitters and receiversPower Fault LED OutActive LED Out Enable port bypass signalsMotor start controls Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesAlpa SEL ID TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Presales Support Seagate Technology support servicesTechnical Support Data Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC