Seagate ST3600002FC manual Invoking DST, Short and extended tests, Short test Function Code 001b

Page 26

A Drive Not Ready condition is reported by the drive under the following conditions:

Motor will not spin

Motor will not lock to speed

Servo will not lock on track

Drive cannot read configuration tables from the disk

In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.

5.2.6.2.2Invoking DST

To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.

5.2.6.2.3Short and extended tests

DST has two testing options:

1.short

2.extended

These testing options are described in the following two subsections.

Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.

Short test (Function Code: 001b)

The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.

Extended test (Function Code: 010b)

The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.

The anticipated length of the Extended test is reported through the Control Mode page.

5.2.6.2.4Log page entries

When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param- eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:

1.The Function Code field is set to the same value as sent in the DST command

2.The Self-Test Results Value field is set to Fh

3.The drive will store the log page to non-volatile memory

After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self- Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero, the test failed for the reason reported in the field.

20

Cheetah NS 10K.2 FC Product Manual, Rev. B

Image 26
Contents Cheetah NS 10K.2 FC ST3600002FC ST3450802FC ST3300602FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance Reference documents Ncits TR-19Cheetah NS 10K.2 FC Product Manual, Rev. B General description Standard features Media descriptionFormatted capacities PerformanceReliability Programmable drive capacity Factory-installed optionsUser-installed accessories Access time Performance characteristicsInternal drive characteristics Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics ST3600002FC ST3450802FC ST3300602FCPrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationRecoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenanceControlling S.M.A.R.T A.R.T. delay times4 S.M.A.R.T Performance impactPredictive failures Reporting controlDetermining rate Thermal monitorDrive Self Test DST State of the drive prior to testingTemperature Log Page 0Dh DST failure definitionShort test Function Code 001b Invoking DSTShort and extended tests Extended test Function Code 010bProduct warranty AbortCheetah NS 10K.2 FC Product Manual, Rev. B DC power requirements Physical/electrical specificationsAC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps General DC power requirement notes DC power requirements for ST3300602FC model Gbit AmpsCurrent profiles Power sequencingConducted noise immunity Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B Power dissipation ST3600002FCST3450802FC ST3300602FC Relative humidity Temperature a. OperatingEnvironmental limits Shock Effective altitude sea level a. OperatingShock and vibration Package size Packaged/product weight Drop height Recommended mountingAcoustics Air cleanlinessVibration a. Operating-normal Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mechanical specifications Mounting configuration dimensionsCheetah NS 10K.2 FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.81 Media Pre-Scan FC-AL system errorsBackground Media Scan Deferred Auto-Reallocation Idle Read After WriteDrive orientation InstallationDrive ID/option selection CoolingDrive mounting Air flowGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Link services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS 10K.2 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Miscellaneous operating features and conditions Supported Feature or conditionPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-SCA pin descriptions Pin Signal name Signal type FC-AL transmitters and receiversPower Fault LED OutMotor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesAlpa SEL ID Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Technical Support Seagate Technology support servicesPresales Support Data Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC