Seagate ST3300602FC 11 SEL6 through SEL0 ID lines, Parallel Enclosure Services Interface ESI

Page 75

Table 25:

Motor start control signals

 

 

 

 

 

Case

Start_2

Start_1

Motor spin function

 

 

 

 

4

High

High

The drive will not spin up.

 

 

 

 

9.5.11SEL_6 through SEL_0 ID lines

The SEL_6 through SEL_0 ID lines determine drive address, and, optionally, for an Enclosure Services Inter- face. When the Parallel ESI line is high, the enclosure backpanel must provide address information on the SEL line. Refer to table 26 for a mapping of SEL to FC-AL physical addresses (AL_PA). You can think of the SEL lines as the equivalent of a backpanel logic plug. The drives does not provide pull up resistors on these lines. The backpanel is required to provide high and low inputs to the SEL_ID lines per the specifications in table 28 on page 71.

Note. Table 26 gives AL_PA values for each SEL value. The first entry in the table is SEL_ID 00. The last entry is SEL_ID 7D. SEL_ID 7E is AL_PA 00 which is not valid for an NL_Port, so is not included in the table. Also, SEL_ID 7Fh does map to a valid AL_PA; however, this value signals the drive that physical addresses are not being assigned using the SEL lines and that a “soft” address will be determined by FC-AL loop initialization.

When the Parallel ESI line is low, the enclosure backpanel logic switches to ESI mode if supported. There are two modes of ESI, seven bits of enclosure status and a bidirectional mode. ESI support and the mode are determined by the drive using a discovery process. Refer to the Fibre Channel Interface Manual for a descrip- tion of ESI operation.

9.5.11.1Parallel Enclosure Services Interface (ESI)

The parallel ESI line is an output from the drive. This line provides the enclosure with an indication of the pres- ent function of the SEL lines. A high level, the default state, indicates the drive requires address information on the SEL lines. A low level indicates the drive is attempting an ESI transfer. The enclosure may not support ESI on any or all drive locations. It may only support the address function. Support of ESI is discovered by the drive. Refer to the Fibre Channel Interface Manual for a description of ESI operations.

Cheetah NS 10K.2 FC Product Manual, Rev. B

69

Image 75
Contents ST3600002FC ST3450802FC ST3300602FC Cheetah NS 10K.2 FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityCompliance Ncits TR-19 Reference documentsCheetah NS 10K.2 FC Product Manual, Rev. B General description Media description Standard featuresPerformance ReliabilityFormatted capacities Factory-installed options User-installed accessoriesProgrammable drive capacity Seek performance Performance characteristicsInternal drive characteristics Access timeST3600002FC ST3450802FC ST3300602FC Format command execution time minutesGeneral performance characteristics Start/stop timeCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsPerformance impact A.R.T. delay times4 S.M.A.R.T Controlling S.M.A.R.TThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingTemperature Log Page 0Dh Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bAbort Product warrantyCheetah NS 10K.2 FC Product Manual, Rev. B DC power requirements for ST3600002FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST3450802FC model Gbit Amps DC power requirements for ST3300602FC model Gbit Amps General DC power requirement notesPower sequencing Conducted noise immunityCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B ST3600002FC Power dissipationST3450802FC ST3300602FC Temperature a. Operating Environmental limitsRelative humidity Effective altitude sea level a. Operating Shock and vibrationShock Recommended mounting Package size Packaged/product weight Drop heightCorrosive environment Air cleanlinessVibration a. Operating-normal AcousticsChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsCheetah NS 10K.2 FC Product Manual, Rev. B Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.81 FC-AL system errors Background Media ScanMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Mode Sense data Inquiry dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Supported Feature or condition Miscellaneous operating features and conditionsPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Seagate Technology support services Presales SupportTechnical Support Warranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC