Seagate ST3300602FC, ST3450802FC, ST3600002FC manual Fibre Channel task management functions

Page 54

9.1.2Fibre Channel task management functions

Table 7 lists the Fibre Channel SCSI Fibre Channel Protocol (FC SCSI FCP) task management functions sup- ported.

Table 7: Fibre Channel SCSI FCP task management functions

Task name

Supported

 

 

Terminate task

No

 

 

Clear ACA

Yes

 

 

Target reset

Yes

 

 

Clear task set

Yes

 

 

Abort task set

Yes

 

 

9.1.3Fibre Channel task management responses

Table 8 lists the FC SCSI FCP response codes returned for task management functions supported.

Table 8: FC SCSI FCP response codes

Function name

Response code

 

 

Function complete

00

 

 

Function not supported

04

 

 

Function reject

05

 

 

48

Cheetah NS 10K.2 FC Product Manual, Rev. B

Image 54
Contents Cheetah NS 10K.2 FC ST3600002FC ST3450802FC ST3300602FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance Reference documents Ncits TR-19Cheetah NS 10K.2 FC Product Manual, Rev. B General description Standard features Media descriptionPerformance ReliabilityFormatted capacities Factory-installed options User-installed accessoriesProgrammable drive capacity Access time Performance characteristicsInternal drive characteristics Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics ST3600002FC ST3450802FC ST3300602FCPrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationRecoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenanceControlling S.M.A.R.T A.R.T. delay times4 S.M.A.R.T Performance impactPredictive failures Reporting controlDetermining rate Thermal monitorDrive Self Test DST State of the drive prior to testingTemperature Log Page 0Dh DST failure definitionShort test Function Code 001b Invoking DSTShort and extended tests Extended test Function Code 010bProduct warranty AbortCheetah NS 10K.2 FC Product Manual, Rev. B DC power requirements Physical/electrical specificationsAC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps General DC power requirement notes DC power requirements for ST3300602FC model Gbit AmpsPower sequencing Conducted noise immunityCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B Power dissipation ST3600002FCST3450802FC ST3300602FC Temperature a. Operating Environmental limitsRelative humidity Effective altitude sea level a. Operating Shock and vibrationShock Package size Packaged/product weight Drop height Recommended mountingAcoustics Air cleanlinessVibration a. Operating-normal Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mechanical specifications Mounting configuration dimensionsCheetah NS 10K.2 FC Product Manual, Rev. B Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.81 FC-AL system errors Background Media ScanMedia Pre-Scan Deferred Auto-Reallocation Idle Read After WriteDrive orientation InstallationDrive ID/option selection CoolingDrive mounting Air flowGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Link services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Mode Sense data Inquiry dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Miscellaneous operating features and conditions Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type FC-AL transmitters and receiversPower Fault LED OutEnable port bypass signals Active LED OutMotor start controls Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesAlpa SEL ID Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Seagate Technology support services Presales SupportTechnical Support Warranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC