be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.

Table 1: Temperature Log Page (0Dh)

Parameter Code

Description

 

 

0000h

Primary Temperature

 

 

0001h

Reference Temperature

 

 

5.2.6Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.

There are two test coverage options implemented in DST:

1.Extended test

2.Short text

The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.

If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.

5.2.6.1DST failure definition

The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.

The following conditions are considered DST failure conditions:

Seek error after retries are exhausted

Track-follow error after retries are exhausted

Read error after retries are exhausted

Write error after retries are exhausted

Recovered errors will not be reported as diagnostic failures.

5.2.6.2Implementation

This section provides all of the information necessary to implement the DST function on this drive.

5.2.6.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

Cheetah NS 10K.2 FC Product Manual, Rev. B

19

Image 25
Contents ST3600002FC ST3450802FC ST3300602FC Cheetah NS 10K.2 FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS 10K.2 FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities User-installed accessories Factory-installed optionsProgrammable drive capacity Internal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time ST3600002FC ST3450802FC ST3300602FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenance4 S.M.A.R.T A.R.T. delay timesControlling S.M.A.R.T Performance impactDetermining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyCheetah NS 10K.2 FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps DC power requirements for ST3300602FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B ST3600002FC Power dissipationST3450802FC ST3300602FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Recommended mounting Package size Packaged/product weight Drop heightVibration a. Operating-normal Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsCheetah NS 10K.2 FC Product Manual, Rev. B Drive internal defects/errors Defect and error managementDrive error recovery procedures 77.81 Background Media Scan FC-AL system errorsMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Inquiry data Mode Sense dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Supported Feature or condition Miscellaneous operating features and conditionsFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Presales Support Seagate Technology support servicesTechnical Support Data Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC