Seagate ST3450802FC Fibre Channel fabric accept login, Fabric Login Accept ACC payload Bytes

Page 58

9.1.9Fibre Channel fabric accept login

Table 14 lists the required content of the Fabric Login Accept (ACC) payload from the fabric.

Table 14: Fabric Login Accept (ACC) payload

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

02

00

00

00

09

09

BB

BB

CF

XX

FS

FS

R_

A_

T0

V_

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

E_

D_

T0

V_

PN

PN

PN

PN

PN

PN

PN

PN

NN

NN

NN

NN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-35

NN

NN

NN

NN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36-47

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Class 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48-51

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-63

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-67

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68-79

 

 

 

 

SO

SO

xx

xx

XX

XX

FS

FS

XX

xx

XX

XX

Class 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80-83

OS

OS

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84-95

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96-99

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-111

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Vendor -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112-115

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XIndicates a four-bit (hex) field is not checked.

x Indicates a single bit is not checked.

BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0).

CF

Common features. This binary field selects the common features requested by the fabric login.

 

MSB

Continuously increasing offset

x

 

 

Random relative offset

x

 

 

Valid version level

x

 

 

N_Port/F_Port

Must = 1, F_Port

 

 

Alternate credit model

Must = 1

 

 

Other bits reserved

xxx XX

FS

Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a

 

multiple of four bytes. The receive buffer field size in the Class 3 parameters is used. The drive uses the lower FS of Fabric Login

 

Accept or N_Port Login when sending frames to an initiator.

PN

Port Name. The fabric port name is saved with the login parameters. If a change of the port name is detected during a FAN, an

 

implicit logout occurs and a LS_RJT is returned to the fabric.

NN

Node Name. The drive does not check or save the node name.

SO

Service Options—Class 3 only.

 

 

MSB

Class valid

Must = 1

 

 

Intermix

x

 

 

Stacked connection req.

xx

 

 

Sequential delivery

Must = 1

 

 

Other bits reserved

xxx XX

52

Cheetah NS 10K.2 FC Product Manual, Rev. B

Image 58
Contents Cheetah NS 10K.2 FC ST3600002FC ST3450802FC ST3300602FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance Reference documents Ncits TR-19Cheetah NS 10K.2 FC Product Manual, Rev. B General description Standard features Media descriptionReliability PerformanceFormatted capacities User-installed accessories Factory-installed optionsProgrammable drive capacity Access time Performance characteristicsInternal drive characteristics Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics ST3600002FC ST3450802FC ST3300602FCPrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationRecoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenanceControlling S.M.A.R.T A.R.T. delay times4 S.M.A.R.T Performance impactPredictive failures Reporting controlDetermining rate Thermal monitorDrive Self Test DST State of the drive prior to testingTemperature Log Page 0Dh DST failure definitionShort test Function Code 001b Invoking DSTShort and extended tests Extended test Function Code 010bProduct warranty AbortCheetah NS 10K.2 FC Product Manual, Rev. B DC power requirements Physical/electrical specificationsAC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps General DC power requirement notes DC power requirements for ST3300602FC model Gbit AmpsConducted noise immunity Power sequencingCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B Power dissipation ST3600002FCST3450802FC ST3300602FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Package size Packaged/product weight Drop height Recommended mountingAcoustics Air cleanlinessVibration a. Operating-normal Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mechanical specifications Mounting configuration dimensionsCheetah NS 10K.2 FC Product Manual, Rev. B Drive internal defects/errors Defect and error managementDrive error recovery procedures 77.81 Background Media Scan FC-AL system errorsMedia Pre-Scan Deferred Auto-Reallocation Idle Read After WriteDrive orientation InstallationDrive ID/option selection CoolingDrive mounting Air flowGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Link services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Inquiry data Mode Sense dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Miscellaneous operating features and conditions Supported Feature or conditionFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-SCA pin descriptions Pin Signal name Signal type FC-AL transmitters and receiversPower Fault LED OutActive LED Out Enable port bypass signalsMotor start controls Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesAlpa SEL ID TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Presales Support Seagate Technology support servicesTechnical Support Data Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC