9.1.7Fibre Channel Process Login Accept

Table 12 lists Cheetah NS 10K.2 FC process login accept payload data.

Table 12:

Process Login Accept (ACC) payload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

02

10

00

14

08

00

 

21

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

00

00

00

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.1.8Fibre Channel fabric login

Table 13 lists the fabric login payload from the drive.

Table 13:

Fabric Login (FLOGI) payload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

04

00

00

00

09

09

00

00

08

00

08

40

00

00

00

00

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

00

00

02

F4

2P

00

CC

CC

CC

UI

UI

UI

02

00

CC

CC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-35

CC

UI

UI

UI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36-47

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Class 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48-51

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-63

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-67

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68-79

 

 

 

 

80

00

00

00

00

00

08

40

00

00

00

00

Class 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80-83

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84-95

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96-99

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-111

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Vendor -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112-115

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).

UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name fields.

PPort identifier field.

1 FLOGI originated on Port A.

2 FLOGI originated on Port B.

Cheetah NS 10K.2 FC Product Manual, Rev. B

51

Image 57
Contents ST3600002FC ST3450802FC ST3300602FC Cheetah NS 10K.2 FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS 10K.2 FC Product Manual, Rev. B General description Media description Standard featuresPerformance ReliabilityFormatted capacities Factory-installed options User-installed accessoriesProgrammable drive capacity Internal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time ST3600002FC ST3450802FC ST3300602FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenance4 S.M.A.R.T A.R.T. delay timesControlling S.M.A.R.T Performance impactDetermining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyCheetah NS 10K.2 FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps DC power requirements for ST3300602FC model Gbit Amps General DC power requirement notesPower sequencing Conducted noise immunityCurrent profiles Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B ST3600002FC Power dissipationST3450802FC ST3300602FC Temperature a. Operating Environmental limitsRelative humidity Effective altitude sea level a. Operating Shock and vibrationShock Recommended mounting Package size Packaged/product weight Drop heightVibration a. Operating-normal Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsCheetah NS 10K.2 FC Product Manual, Rev. B Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.81 FC-AL system errors Background Media ScanMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Mode Sense data Inquiry dataCheetah NS 10K.2 FC inquiry data Bytes Data hex Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Supported Feature or condition Miscellaneous operating features and conditionsPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Seagate Technology support services Presales SupportTechnical Support Warranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC