Seagate ST3600002FC, ST3300602FC manual Vibration a. Operating-normal, Acoustics, Air cleanliness

Page 41

6.4.4.2Vibration a. Operating—normal

The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding

10 - 300 Hz

1 G RMS (0 to peak)

301 - 500 Hz

0.5 G RMS (0 to peak)

Vibration may be applied in the X, Y, or Z axis.

b.Operating—abnormal

Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:

15 minutes of duration at major resonant frequency

Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.

Operating abnormal translational random flat profile

5 - 500 Hz

0.75 G (0 to peak)

10-300 Hz

0.0029 G2/Hz

c.Non-operating

The limits of non-operating vibration shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.

The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding

5 - 22 Hz

0.25 G (0 to peak) (0 to peak, linear, swept sine, 0.5 octave/min)

22 - 350 Hz

3 G (0 to peak)

(0 to peak, linear, swept sine, 0.5 octave/min)

350 - 500 Hz

1 G (0 to peak)

(0 to peak, linear, swept sine, 0.5 octave/min)

Vibration may be applied in the X, Y, or Z axis.

6.4.5Acoustics

Sound power during idle mode shall be 3.4 bels typical when measured to ISO 7779 specification. Sound power while operating shall be 3.6 bels typical when measured to ISO 7779 specification.

There will not be any discrete tones more than 10 dB above the masking noise on typical drives when mea- sured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the masking noise on any drive.

6.4.6Air cleanliness

The drive is designed to operate in a typical office environment with minimal environmental control.

6.4.7Corrosive environment

Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845. However, this accelerated testing cannot duplicate every potential application environment.

Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corro- sive chemicals as electronic drive component reliability can be affected by the installation environment. The sil- ver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chloride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic components

Cheetah NS 10K.2 FC Product Manual, Rev. B

35

Image 41
Contents ST3600002FC ST3450802FC ST3300602FC Cheetah NS 10K.2 FCPage Contents Installation Seagate Technology support services Cheetah NS 10K.2 FC Product Manual, Rev. B Scope Cheetah NS 10K.2 FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS 10K.2 FC Product Manual, Rev. B General description Media description Standard featuresFormatted capacities PerformanceReliability Programmable drive capacity Factory-installed optionsUser-installed accessories Internal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time ST3600002FC ST3450802FC ST3300602FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenance4 S.M.A.R.T A.R.T. delay timesControlling S.M.A.R.T Performance impactDetermining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyCheetah NS 10K.2 FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3600002FC model Gbit AmpsDC power requirements for ST3450802FC model Gbit Amps DC power requirements for ST3300602FC model Gbit Amps General DC power requirement notesCurrent profiles Power sequencingConducted noise immunity Cheetah NS 10K.2 FC Product Manual, Rev. B Cheetah NS 10K.2 FC Product Manual, Rev. B ST3600002FC Power dissipationST3450802FC ST3300602FC Relative humidity Temperature a. OperatingEnvironmental limits Shock Effective altitude sea level a. OperatingShock and vibration Recommended mounting Package size Packaged/product weight Drop heightVibration a. Operating-normal Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive Mounting configuration dimensions Mechanical specificationsCheetah NS 10K.2 FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.81 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS 10K.2 FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS 10K.2 FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS 10K.2 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header Mode Pages 00 00 05 12 8B 00 50 Supported Feature or condition Miscellaneous operating features and conditionsPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Cheetah NS 10K.2 FC Product Manual, Rev. B Technical Support Seagate Technology support servicesPresales Support Data Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index FCP Flogi Plogi Page See also cooling Page Seagate Technology LLC