Western Telematic NPS-2HD manual Back Panel, Circuit Breaker 115 VAC, 20 Amps

Page 10

NPS-2HDHeavyDutyNetworkPowerSwitch;User'sGuide

2.2. Back Panel

Figure2.2:BackPanel

￿Bus 2 (Plug 2): Includes the following components:

A)Power Inlet: Supplies power for Bus 2.

B)Circuit Breaker: 115 VAC, 20 Amps

C)Switched Outlet: Each bus can switch up to 20 Amps.

￿Bus 1 (Plug 1): Same as Item 1 above, except the Bus 1 Power Inlet supplies power to Bus 1.

￿Network Port and Activity Indicator: A 10BaseT, RJ45 Ethernet port for connection to your TCP/IP network. To communicate via Network, you must first specify network parameters as described in Section 5.6.

Note: The NPS-2HD features a 10BaseT interface. When connecting the NPS to a 100BaseT interface, note that most 100BaseT router switches will autosense to determine if the device is 100BaseT or 10BaseT and then configure the network interface accordingly. If your router switch does not autosense, then the network interface port must be manually set to 10BaseT.

￿Modem Port: A Male RS-232, DB9 Connector, DTE configuration. For connection to an external modem.

￿Console Port: A Male RS-232, DB9 Connector, DTE configuration. For connection to a local PC.

￿Option Switches: A bank of four DIP Switches which select default settings for the baud rate and other features.

￿Default Button: Used in conjunction with the Reset Button to reset the unit to defaults (see Section 4.3.)

￿Reset Button: Used in conjunction with the Default

2-2Button to reset the unit to defaults (see Section 4.3.)

Image 10 Contents
NPS-2HD Page Nameplate Power Warning Rack Mount InstallationDisconnect Power VentilationCable OptionSwichesNetwokCable SystemModeOnly Intelligent Power Control IntroductionTypographic Conventions Unit Description Front PanelBack Panel Circuit Breaker 115 VAC, 20 AmpsQuick Start Guide Page QuickStartGuide NPS-2HDHeavyDutyNetworkPowerSwitchUsersGuide Power Connection InstallationCable Clamp Installation 1OutputCableClampInstallation Output Cable ClampInstallation Input Cable ClampOption Switches Disconnect TimeoutDefault Button / Reset Button Local Reset Unit to DefaultsDefault Parameters Option Connecting the Network Cable Connecting an External ModemConsole Port Connection Configuration System Mode and User ModeCommunicating with the NPS =AllPlugswithAccess NPS Command/Menu Conventions Defining General ParametersButtonMode NPS-2HDHeavyDutyNetworkPowerSwitchUsersGuide Configuration Plug ParametersPage 00-40-05-5e-f3-90 Network ParametersImplementing IP Security Configuration Save Configuration Parameters Access the NPS-2HD Command Mode OperationMrmaio Displaying Plug StatusBoot/On/Off Commands OperationOFF POWER2 or /OF POWER2 and press Enter Default Command Automated ModeNPS-2HDHeavyDutyNetworkPowerSwitchUsersGuide Reset Network Port Other CommandsLogin as Different User Exit / DisconnectManual Operation Operating TipsSaving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Interface Descriptions Console Port InterfaceApx-2 Modem Port InterfaceSpecifications Input Connector IEC-320-C19 InletCustomer Service Apx-4Appendices Trademark and Copyright InformationApx-6 4-6 FrontactoryPanSttigsAddresslIndicators.FIndex 4-6,6-8 OnsolePortANameOwnrship PowerInlet58,643
Related manuals
Manual 52 pages 21.1 Kb